Medicine & Science in Sports & Exercise · 2019 · 22 citations · 34 references
Life SciencesPhysiologyExercise PhysiologyExercise TestingPulmonary Function TestingAerobic CapacityCardiopulmonary Exercise TestingCardiorespiratory FitnessExercise Tolerance AssessmentMetabolic Responses To ExercisePhysical FitnessConstant-load Exercise TestingExercise Tolerance EvaluationMuscle Power TestingNear-infrared Spectroscopy AssessmentOxygenationPhysiological Characterization
INTRODUCTION/PURPOSE: Critical power (CP) is a fundamental parameter defining high-intensity exercise tolerance; however, its physiological determinants are incompletely understood. The present study determined the impact of hyperoxia on CP, the time constant of phase II pulmonary oxygen uptake kinetics (τV˙O2), and muscle oxygenation (assessed by near-infrared spectroscopy) in nine healthy men performing upright cycle ergometry. METHODS: Critical power was determined in normoxia and hyperoxia (fraction of inspired O2 = 0.5) via four severe-intensity constant load exercise tests to exhaustion on a cycle ergometer, repeated once in each condition. During each test, τV˙O2 and the time constant of muscle deoxyhemoglobin kinetics (τ[HHb]), alongside absolute concentrations of muscle oxyhemoglobin ([HbO2]), were determined. RESULTS: Critical power was greater (hyperoxia, 216 ± 30 W vs normoxia, 197 ± 29 W; P < 0.001), whereas W' was reduced (hyperoxia, 15.4 ± 5.2 kJ; normoxia, 17.5 ± 4.3 W; P = 0.037) in hyperoxia compared with normoxia. τV˙O2 (hyperoxia, 35 ± 12 s vs normoxia, 33 ± 10 s; P = 0.33) and τ[HHb] (hyperoxia, 11 ± 5 s vs normoxia, 14 ± 5 s; P = 0.65) were unchanged between conditions, whereas [HbO2] during exercise was greater in hyperoxia compared with normoxia (hyperoxia, 73 ± 20 vs normoxia, 66 ± 15 μM; P < 0.001). CONCLUSIONS: This study provides novel insights into the physiological determinants of CP and by extension, exercise tolerance. Microvascular oxygenation and CP were improved during exercise in hyperoxia compared with normoxia. Importantly, the improved microvascular oxygenation afforded by hyperoxia did not alter τV˙O2, suggesting that microvascular O2 availability is an independent determinant of the upper limit for steady-state exercise, that is, CP.
34
Metabolic and respiratory profile of the upper limit for prolonged exercise in man
David C. Poole, Susan A. Ward, Gerald W. Gardner et al. · Ergonomics · 1988 · 777 citations
Parameters of ventilatory and gas exchange dynamics during exercise
Brian J. Whipp, Susan Ward, N. Lamarra et al. · Journal of Applied Physiology · 1982 · 645 citations
Andrew M. Jones, Daryl P. Wilkerson, Fred J. DiMenna et al. · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · 2007 · 469 citations