BMC Ophthalmology · 2019 · 10 citations · 1 references
MedicineOphthalmologySurgeryImplant SurgeryOcular PathologyOphthalmic SurgeryGlaucomaGlaucoma SurgeryOcular ImplantsUveal SurgeryGlaucoma Drainage ImplantsGlaucoma Filtering SurgeryHydrogel Ocular ImplantsIntraocular Pressure ElevationIntraocular Pressure ManagementIntraocular Pressure ReductionMinimal Invasive AccessMinimally Invasive Glaucoma Surgery
BACKGROUND: The placement of a XEN gel stent is an ab-interno, minimally invasive glaucoma surgery which provides a subconjunctival drainage pathway and decreases intraocular pressure (IOP). CASE PRESENTATION: A 75-year-old male patient who had undergone XEN45 gel implantation after phacoemulsification and intraocular lens implantation appealed to the clinic. A filtration bleb was seen that extended through the nasal 180 degrees of the eye which caused ectropion of the lower eyelid. The value of the IOP was 12 mm Hg (mmHg). By the "Drainage Channel with Sutures" method this complication was effectively treated. As with every new method, there is a lack of knowledge about long-term outcomes in terms of effectiveness, technique and complications. CONCLUSION: The "Drainage Channel with Sutures" method has not been described in the literature yet. By this minimal invasive method, hypertrophic bleb complication of XEN gel implant has been successfully treated.
1
XEN Glaucoma Implant with Mitomycin C 1-Year Follow-Up: Result and Complications
Ahmed Galal, Alper Bilgic, Rasha Eltanamly et al. · Journal of Ophthalmology · 2017 · 178 citations · Full text
Medicine, Ophthalmology, Surgery +17