Acta Ophthalmologica · 2019 · 106 citations · 39 references
Health ProfessionsComputer ScienceOphthalmologyClinical Vision ScienceComputer VisionOcular ImagingAge-related Macular DegenerationDiabetic RetinopathyMacular DegenerationMacular DiseaseMacular DisordersRetinal ExaminationAge-related Macular Degeneration DetectionAge-related Macular Degeneration DiagnosisColor Fundus ImagingDiabetic Retinopathy DetectionDiabetic Retinopathy GradingIndividual IdentificationJoint DetectionRetinal Image Grading
PURPOSE: To validate the performance of a commercially available, CE-certified deep learning (DL) system, RetCAD v.1.3.0 (Thirona, Nijmegen, The Netherlands), for the joint automatic detection of diabetic retinopathy (DR) and age-related macular degeneration (AMD) in colour fundus (CF) images on a dataset with mixed presence of eye diseases. METHODS: Evaluation of joint detection of referable DR and AMD was performed on a DR-AMD dataset with 600 images acquired during routine clinical practice, containing referable and non-referable cases of both diseases. Each image was graded for DR and AMD by an experienced ophthalmologist to establish the reference standard (RS), and by four independent observers for comparison with human performance. Validation was furtherly assessed on Messidor (1200 images) for individual identification of referable DR, and the Age-Related Eye Disease Study (AREDS) dataset (133 821 images) for referable AMD, against the corresponding RS. RESULTS: Regarding joint validation on the DR-AMD dataset, the system achieved an area under the ROC curve (AUC) of 95.1% for detection of referable DR (SE = 90.1%, SP = 90.6%). For referable AMD, the AUC was 94.9% (SE = 91.8%, SP = 87.5%). Average human performance for DR was SE = 61.5% and SP = 97.8%; for AMD, SE = 76.5% and SP = 96.1%. Regarding detection of referable DR in Messidor, AUC was 97.5% (SE = 92.0%, SP = 92.1%); for referable AMD in AREDS, AUC was 92.7% (SE = 85.8%, SP = 86.0%). CONCLUSION: The validated system performs comparably to human experts at simultaneous detection of DR and AMD. This shows that DL systems can facilitate access to joint screening of eye diseases and become a quick and reliable support for ophthalmological experts.
39
Gradient-based learning applied to document recognition
Yann LeCun, Léon Bottou, Yoshua Bengio et al. · Proceedings of the IEEE · 1998 · 58.2K citations · Full text
Going deeper with convolutions
Christian Szegedy, Wei Liu, Yangqing Jia et al. · 2015 · 46.8K citations
Densely Connected Convolutional Networks
Gao Huang, Zhuang Liu, Laurens van der Maaten et al. · 2017 · 44.7K citations