Rapid Communications in Mass Spectrometry · 2019 · 12 citations · 40 references
Natural SciencesChemistryAnalytical ChemistryMass Spectrometric AnalysisOrganic ChemistryGas ChromatographyInstrumental AnalysisMass SpectrometryMetabolite IdentificationVolatile Organic CompoundsVolatile Substance AnalysisElectrospray IonizationGas Chromatography-mass SpectrometryMetabolite AnalysisSecondary Ion Mass SpectrometryVolatile Compound AnalysisVolatile Organic Compound AnalysisVolatile Organic Compound DetectionVolatile Organic Compounds Analysis
Nalophan bags are commonly used to collect breath samples for volatile metabolite analysis. Volatile organic compounds (VOCs) released from the polymer can, however, be mistaken as breath metabolites when analyses are performed by selected ion flow tube mass spectrometry, SIFT-MS, or techniques that depend on a proper understanding of ion chemistry. METHODS: Three analytical techniques were used to analyse the VOCs released into the nitrogen used to expand Nalophan bags, viz. gas chromatography/mass spectrometry (GC/MS), secondary electrospray ionization mass spectrometry (SESI-MS) and selected ion flow tube mass spectrometry (SIFT-MS). The most significant VOCs were identified and quantified by SIFT-MS as a function of storage time, temperature and humidity. RESULTS: The consistent results obtained by these three analytical methods identify 1,2-ethanediol (ethylene glycol) and 2-methyl-1,3-dioxolane as the major VOCs released by the Nalophan. Their concentrations are enhanced by increasing the bag storage temperature and time, reaching 170 parts-per-billion by volume (ppbv) for ethylene glycol and 34 ppbv for 2-methyl-1,3-dioxolane in humid nitrogen (absolute humidity of 5%) contained in an 8-L Nalophan bag stored at 37°C for 160 min. CONCLUSIONS: reagent ions for SIFT-MS and SESI-MS analyses, the following analyte ions (m/z values) are affected by the Nalophan impurities: 45, 63, 81, 89 and 99, which can compromise analyses of acetaldehyde, ethylene glycol, monoterpenes, acetoin, butyric acid, hexanal and heptane.
40
Noninvasive detection of lung cancer by analysis of exhaled breath
Amel Bajtarevic, Clemens Ager, Martin Pienz et al. · BMC Cancer · 2009 · 586 citations · Full text
Medicine, Oncology, Cancer Screening +10
Breath Sensors for Health Monitoring
Andreas T. Güntner, Sebastian Abegg, Karsten Königstein et al. · ACS Sensors · 2019 · 398 citations
On the use of Tedlar® bags for breath-gas sampling and analysis
Jonathan Beauchamp, Jens Herbig, R A Gutmann et al. · Journal of Breath Research · 2008 · 223 citations