International Journal of Retina and Vitreous · 2019 · 44 citations · 49 references
Health ProfessionsOphthalmologyVision ScienceBiomedical ImagingDiagnostic ImagingOcular ImagingDiabetic RetinopathyImage QualityImage Quality AssessmentOptical Coherence TomographyRetinal Image QualityRetinal ImagingImage Acquisition QualityNon-proliferative Diabetic RetinopathyOptical Coherence Tomography AngiographyRepeatabilityRetinal AngiographyRetinal Image Quality AssessmentRetinal Vasculature ImagingSignal Strength Evaluation
Abstract Background This study aimed to determine the relationship between image quality and measurement repeatability of optical coherence tomography angiography (OCTA) parameters in patients with non-proliferative diabetic retinopathy. Methods A total of 100 eyes of 50 patients were included in the study. Three OCTA images were obtained consecutively during one session of imaging in all patients using the RTVue AngioVue OCTA device. We applied the signal strength index (SSI) provided by the RTVue system to define scan quality. Superficial vessel density (VD) in the central 3 × 3 mm macular and in the perifoveal region, as well as foveal avascular zone (FAZ) area were evaluated by the AngioAnalytics software for each scan from three consecutive measurements, whereby measurement repeatability of the OCTA parameters were calculated. The effect of SSI value on OCTA parameters, as well as on measurement errors was assessed. Results Values of SSI ranged from 30 to 85 with an overall mean of 61.79 ± 10.38. Mean SSI values showed significant positive correlation with the mean retinal capillary vessel density values, but not with non-flow area. Repeatability of OCTA parameters was generally improved with higher SSI values. We calculated a mean correction factor of 0.22% (95% CI 0.20–0.24 µm; p < 0.001) for VD at the 3 × 3 mm macular scan, 0.23% (95% CI 0.21–0.26%; p < 0.001) for perifoveal VD and − 0.001 mm 2 (95% CI − 0.001 to 0.002; p = 0.001) for the non-flow area for each unit increase in SSI for the comparison of images with different SSI values. Conclusions The influence of image quality on OCTA metrics should be considered for image comparisons during follow-up to avoid misinterpretation of small changes in OCTA parameters in patients with diabetes.
49
The Wisconsin Epidemiologic Study of Diabetic Retinopathy
Ronald Klein · Archives of Ophthalmology · 1984 · 1.9K citations
The Wisconsin Epidemiologic Study of Diabetic Retinopathy
Ronald Klein · Archives of Ophthalmology · 1984 · 1.5K citations
Early Photocoagulation for Diabetic Retinopathy
E Gregersen, Hans‐Walther Larsen · Ophthalmology · 1991 · 1.3K citations