Experimental Physiology · 2019 · 20 citations · 62 references
Life SciencesKinesiologyPhysiologyExercise PhysiologyFluid DynamicsRheologyBlood RheologyBlood ViscosityCardiovascular PhysiologyHemodynamicsShear ThinningViscous FlowBlood FlowBlood Flow DynamicsExercise-induced Viscosity ChangesShear RateShear StressShear ViscosityVascular ResistanceViscosity
New Findings What is the central question of this study? Quantitative values of shear rate‐specific blood viscosity and shear stress in the human macrovasculature in response to exercise hyperaemia are unknown. What is the main finding and its importance? Using the handgrip exercise model, we showed that an increase in brachial artery shear rate led to a decrease in blood viscosity, despite concomitant haemoconcentration. This shear‐thinning behaviour of blood, secondary to increased erythrocyte deformability, blunted the expected increase in brachial artery shear stress based on shear rate prediction. Our data yield new insights into the magnitude and regulation of macrovascular blood viscosity and shear stress in physiological conditions of elevated metabolic demand and blood flow in humans. Abstract Blood viscosity is a well‐known determinant of shear stress and vascular resistance; however, accurate quantitative assessments of shear rate‐specific blood viscosity in the macrovasculature in conditions of elevated blood flow are inherently difficult, owing to the shear‐thinning behaviour of blood. Herein, 12 men performed graded rhythmic handgrip exercise at 20, 40, 60 and 80% of their maximal workload. Brachial artery shear rate and diameter were measured via high‐resolution Duplex ultrasound. Blood was sampled serially from an i.v . cannula in the exercising arm for the assessment of blood viscosity (cone‐plates viscometer). We measured ex vivo blood viscosity at 10 discrete shear rates within the physiological range documented for the brachial artery in basal and exercise conditions. Subsequently, the blood viscosity data were fitted with a two‐phase exponential decay, facilitating interpolation of blood viscosity values corresponding to the ultrasound‐derived shear rate. Brachial artery shear rate and shear stress increased in a stepwise manner with increasing exercise intensity, reaching peak values of 940 ± 245 s −1 and 3.68 ± 0.92 Pa, respectively. Conversely, brachial artery shear rate‐specific blood viscosity decreased with respect to baseline values throughout all exercise intensities by ∼6–11%, reaching a minimal value of 3.92 ± 0.35 mPa s, despite concomitant haemoconcentration. This shear‐thinning behaviour of blood, secondary to increased erythrocyte deformability, blunted the expected increase in shear stress based on shear rate prediction. Consequently, the use of shear stress yielded a higher slope for the brachial artery stimulus versus dilatation relationship than shear rate. Collectively, our data refute the use of shear rate to infer arterial shear stress‐mediated processes.
62
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
New guidelines for hemorheological laboratory techniques
Oğuz K. Başkurt, M. Boynard, G. Cokelet et al. · Clinical Hemorheology and Microcirculation · 2009 · 496 citations · Full text
Shear Stress Mediates Endothelial Adaptations to Exercise Training in Humans
Toni M. Tinken, Dick H. J. Thijssen, Nicola Hopkins et al. · Hypertension · 2010 · 476 citations · Full text