Pacing and Clinical Electrophysiology · 2019 · 67 citations · 20 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyAblation TherapyAtrial FibrillationCardiac CatheterizationCatheter AblationFluoroscopy-guided ProceduresCatheter Ablation MappingEchocardiographic GuidanceFluoroscopic GuidanceFluoroscopy-guided AblationInteratrial SeptumIntracardiac EchocardiographyIntracardiac MappingSurgical Ablation
INTRODUCTION: Atrial fibrillation (AF) ablation requires access to the left atrium (LA) via transseptal puncture (TP). TP is traditionally performed with fluoroscopic guidance. Use of intracardiac echocardiography (ICE) and three-dimensional mapping allows for zero fluoroscopy TP. OBJECTIVE: To demonstrate safety and efficacy of zero fluoroscopy TP using multiple procedural approaches. METHODS: Patients undergoing AF ablation between January 2015 and November 2017 at five institutions were included. ICE and three-dimensional mapping were used for sheath positioning and TP. Variable technical approaches were used across centers including placement of J wire in the superior vena cava with ICE guidance followed by dragging down the transseptal sheath into the interatrial septum, or guiding the transseptal sheath directly to the interatrial septum by localizing the ablation catheter with three-dimensional mapping and replacing it with the transseptal needle once in position. In patients with pacemaker/implantable cardiac defibrillator leads, pre-/poststudy device interrogation was performed. RESULTS: , ejection fraction 57.7 ± 10.9%) with 100% success. No punctures required fluoroscopy. Two pericardial effusions, two pericardial tamponades requiring pericardiocentesis, and one transient ischemic attack were observed during the overall ablation procedure, with a total complication rate of 0.7%. There were no other periprocedural complications related to TP, including intrathoracic bleeding, stroke, or death both immediately following TP and within 30 days of the procedure. In patients with intracardiac devices, no device-related complications were observed. CONCLUSION: TP can be safely and effectively performed without the need for fluoroscopy.
20
Sana M. Al‐Khatib, William G. Stevenson, Michael J. Ackerman et al. · Circulation · 2017 · 401 citations · Full text
Transseptal left atrial puncture
John Ross, Eugene Braunwald, Andrew G. Morrow · The American Journal of Cardiology · 1959 · 252 citations
Medicine, Cardiology, Surgery +8