MedicineOphthalmologySurgeryClinical Vision ScienceOphthalmic SurgeryRefractive SurgeryPreoperative Refractive EvaluationPresbyopia CorrectionPresbyopia ManagementRefractive ErrorRefractive Error AssessmentDefocusDefocus ProfilesNear Vision CorrectionProspective Case StudyStatic Visual AcuitySurgical Presbyopia CorrectionTrifocal Intraocular LensesVisual Acuity Improvement
PURPOSE: To evaluate the defocus curves of 4 presbyopia-correcting intraocular lenses (IOLs). SETTING: Department of Ophthalmology, Goethe University, Frankfurt, Germany. DESIGN: Prospective case series. METHODS: Patients included in the study had bilateral surgery with implantation of diffractive panfocal, diffractive trifocal, segmental refractive (SegRef), or extended-depth-of-focus (EDOF) presbyopia-correcting IOLs. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate and near visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuities, defocus curve, and spectacle independence were measured. RESULTS: The UDVA and CDVA were not significantly different between groups (P > .05); however, the EDOF group had worse near CDVA (P < .001). The trifocal and EDOF groups showed better DCIVA than the panfocal and SegRef group at 80 cm (P < .001); the EDOF and panfocal groups had comparable DCIVA at 60 cm (P > .05). Defocus curves showed no significant between-group differences from 4 m to 2 m (P > .05). The EDOF group had better visual acuity from 1 m to 67 cm than the trifocal and SegRef groups and better visual acuity than the panfocal group at 1 m (P > .05). Compared with the other IOLs, the panfocal IOL yielded significantly better visual acuity at 50 cm (P < .001) and the EDOF IOL worse visual acuity at 40 cm (P < .01). There was a significant difference in spectacle independence between the panfocal group and EDOF group (P < .05) but no difference between the other groups. CONCLUSIONS: The 4 IOLs provided equally good CDVA. The EDOF IOL yielded slightly better DCIVA but worse DCNVA than the other IOLs. Only the panfocal IOL gave better DCIVA at 50 cm.
26
Wolfgang Haigis, Barbara A.M. Lege, Naomi R. Miller et al. · Graefe s Archive for Clinical and Experimental Ophthalmology · 2000 · 765 citations
Global Vision Impairment Due to Uncorrected Presbyopia
Brien A. Holden · Archives of Ophthalmology · 2008 · 435 citations · Full text
European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular Lens
Thomas Kohnen, David W. Allen, C Boureau et al. · Ophthalmology · 2006 · 281 citations
Medicine, Ophthalmology, Surgery +11