Biomedical Journal · 2019 · 15 citations · 34 references
MedicineRadiologyDiagnostic RadiologyRadiation DosimetryRadiation MeasurementComputed TomographyComputed Tomography PhysicsMedical Radiation ShieldingPhantom DosimetryRadiation Dose MeasurementRadiographic ImagingComputed Tomography Dose MeasurementContrast-to-noise Ratio EstimationImage Noise AssessmentPhantom-based Dose MeasurementRadiographic Image QualityShielding Effects On Background MeasurementsThermoluminescent DosimetersX-ray Spectra
BACKGROUND: To quantify image quality and radiation doses in regions adjacent to and distant from bismuth shields in computed tomography (CT). METHODS: An American College of Radiology accreditation phantom with four solid rods embedded in a water-like background was scanned to verify CT number (CTN) accuracy when using bismuth shields. CTNs, image noise, and contrast-to-noise ratios (CNRs) were determined in the phantom at 80-140 kVp. Image quality was investigated on image portions in the zones adjacent (A zone) to and distant (D zone) from a bismuth shield. Surface radiation doses were measured using thermoluminescent dosimeters. Streak artefacts were graded on a 3-point-scale. RESULTS: Changes in CTN caused by a bismuth shield resulted in changes in X-ray spectra. CTN changes were more apparent in the A zone than in the D zone, particularly for a low tube voltage. The degrees of CTN changes and image noise were proportional to the thickness of the bismuth shields. A 1-ply bismuth shield reduced surface radiation doses by 7.2%-15.5%. The overall CNRs were slightly degraded, and streak artefacts were acceptable. CONCLUSIONS: Using a bismuth shield could result in significant CTN changes and perceivable artefacts, particularly for a superficial organ close to the shield, and is not recommended for quantification CT examinations or follow-up CT examinations.
34