Radiation Oncology · 2019 · 72 citations · 34 references
MedicineOncologyRadiation OncologyClinical Decision SupportClinical InformaticsTreatment PlanningCancer Treatment PlanningPlan OptimizationRadiation Treatment PlanningIterative Design ProcessIterative LearningModel-based Treatment PlanningPlan Quality AssessmentPlan Quality MetricsPlan ValidationTreatment Planning Methodology
PURPOSE: To determine if the performance of a knowledge based RapidPlan (RP) planning model could be improved with an iterative learning process, i.e. if plans generated by an RP model could be used as new input to re-train the model and achieve better performance. METHODS: Clinical VMAT plans from 83 patients presenting with head and neck cancer were selected to train an RP model, CL-1. With this model, new plans on the same patients were generated, and subsequently used as input to train a novel model, CL-2. Both models were validated on a cohort of 20 patients and dosimetric results compared. Another set of 83 plans was realised on the same patients with different planning criteria, by using a simple template with no attempt to manually improve the plan quality. Those plans were employed to train another model, TP-1. The differences between the plans generated by CL-1 and TP-1 for the validation cohort of patients were compared with respect to the differences between the original plans used to build the two models. RESULTS: to serial organs increased (but not significantly). The different models CL-1 and TP-1 were able to yield plans according to each original strategy. CONCLUSION: A refined RP model allowed the generation of plans with improved quality, mostly for parallel organs at risk and, possibly, also the intrinsic model quality.
34