IEEE Access · 2019 · 36 citations · 34 references
EngineeringElectrical EngineeringNeuroscienceBioinstrumentationBiomedical Signal ProcessingElectrophysiologyBiomedical Signal FilteringDigital Signal ProcessingElectrocardiographyElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographyArtifact Removal In ElectroencephalographyEeg Noise ReductionEeg Signal ProcessingElectrophysiological RecordingsIndependent Component AnalysisNotch FilteringRecursive Least Squares FilteringSignal Filtering
Electroencephalogram (EEG) is a common tool for medical diagnosis, cognitive research, and managing neurological disorders. However, EEG is usually contaminated with various artifacts, making it difficult to interpret EEG data. In this study, a recursive least square (RLS) notch filter was developed to effectively suppress electrocardiogram (ECG) artifacts from EEG recordings. ECG artifacts were estimated and modeled using the instantaneous frequency of the cardiac cycle. Then it was adaptively estimated using a RLS filter and directly subtracted from contaminated EEG data. Based on the validation measures of improvement of normalized power spectrum (INPS), mean square error (MSE) and information quantity (IQ), the performance of ECG artifacts suppression was compared among the proposed RLS approach, independent component analysis (ICA) and blind deconvolution method under information maximization (Infomax) on simulated and animal experimental data. Simulation data demonstrated that INPS of RLS method (19.75(18.37,20.95) dB) was significantly higher than that of ICA (4.35(3.35,5.41) dB) and Infomax (5.76(4.60,6.88) dB). Meanwhile, MSE of RLS method (0.20(0.08,0.53) μV <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) was considerably lower than that of ICA (5.59(2.35,19.79) μV <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) and Infomax (3.21(1.01,10.69) μV <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ). Animal experimental data showed that INPS was 1.76(0.42,9.40) dB for RLS method, which was dramatically higher than that of ICA (0.02(0.00,0.14) dB) and Infomax (0.57(0.08,2.45) dB). The calculated IQ for RLS method (0.331(0.021,0.584)) was relatively lower than that of raw EEG (0.350(0.070,0.586)), ICA (0.350(0.069,0.581)) and Infomax (0.341(0.050,0.585)). The RLS notch filter can effectively eliminate ECG artifacts from EEG and preserve the majority of EEG information with little loss.
34
Steven C. Rogers · Control Engineering Practice · 1996 · 9.3K citations
A Real-Time QRS Detection Algorithm
Jiapu Pan, W.J. Tompkins · IEEE Transactions on Biomedical Engineering · 1985 · 7.7K citations
Adaptive noise cancelling: Principles and applications
Bernard Widrow, John R. Glover, J. McCool et al. · Proceedings of the IEEE · 1975 · 3.9K citations