Cornea · 2019 · 92 citations · 9 references
MedicineOphthalmologySurgeryAnterior SegmentOphthalmic SurgeryRefractive SurgeryCataract SurgeryLens SurgeryPhakic Intraocular LensesPolypropyleneScleral Tunnel Construction
PURPOSE: To develop a novel, sutureless, single-piece, nonfoldable intraocular lens (IOL) intrascleral fixation technique based on the existing Malbran IOL scleral fixation and Yamane double-needle techniques. METHODS: The novel method uses a 5.0 polypropylene suture and a bipolar cautery to create 2 flanges in the eyelets of the IOL and 2 flanges outside to insert inside the scleral tunnel and thus fixate the IOL. RESULTS: This technique had been applied in 4 patients with aphakia after phacoemulsification complications. The mean preoperative and postoperative corrected distance visual acuities were 0.45 ± 0.17 and 0.67 ± 0.27 (Snellen decimal units), respectively. CONCLUSIONS: The 4-flanged technique improves and simplifies the existing single-piece, nonfoldable IOL intrascleral fixation techniques.
9
Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique
Shin Yamane, Shimpei Sato, Maiko Maruyama-Inoue et al. · Ophthalmology · 2017 · 662 citations
Medicine, Ophthalmology, Surgery +6
James S. Lewis · Ophthalmic surgery, lasers & imaging retina · 1991 · 202 citations