Journal of Ophthalmology · 2019 · 10 citations · 15 references
MedicineOphthalmologySurgeryMyopia ManagementOphthalmic SurgeryRefractive SurgeryHigh MyopiaMyopia ControlMyopia Control LensesMyopia CorrectionPhakic Intraocular LensesRefractive ErrorAnterior Chamber Phakic Intraocular LensHigh Myopia CorrectionIntraocular Lens-based Myopia CorrectionMyopia Management Contact LensesParticipant Data ExtractionPhakic Intraocular Lens PlacementPosterior Chamber Intraocular LensesPosterior Chamber Phakic Intraocular Lens
Purpose . To evaluate the efficacy of phakic posterior chamber intraocular lens with a central hole (ICL V4c) in treating patients with moderate to high myopia. Methods . PubMed, Embase, Cochrane Library, Clinical Trial, China Biomedical Literature Database (CBM), China National Knowledge Infrastructure (CNKI), and China Science Periodical Database (CSPD) were searched online. The search included publications from the building of the library until December 2018. All randomized controlled trials containing moderate to high myopia treated by phakic posterior chamber intraocular lens with a central hole were collected. Literature search, screening literature, data extraction, and quality evaluation were independently performed by two reviewers. Meta-analysis was performed using RevMan 5.3 software. Results . Meta-analysis results based on five randomized controlled trials showed that ICL V4c and ICL without a central hole had similar UCVA results (SMD = 0.08, 95% CI (−0.71, 0.88), <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mrow><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mn>0.84</mml:mn></mml:mrow></mml:math>), SE (SMD = −0.18, 95% CI (−0.52, 0.15), <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mrow><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mn>0.29</mml:mn></mml:mrow></mml:math>), BCVA (SMD = −0.27, 95% CI (−0.93, 0.40), <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mrow><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mn>0.43</mml:mn></mml:mrow></mml:math>), and IOP (SMD = 0.03, 95% CI (−0.24, 0.30), <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M4"><mml:mrow><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mn>0.84</mml:mn></mml:mrow></mml:math>), and the difference was not statistically significant. In addition, no complications that could jeopardize vision occurred. Conclusions . Implanting ICL V4c in patients with moderate to high myopia is safe and effective.
15
Implantable Collamer Lens for Myopia: Assessment 12 Years After Implantation
Tomás Moya, Jaime Javaloy, Robert Montés‐Micó et al. · Journal of Refractive Surgery · 2015 · 145 citations
Medicine, Ophthalmology, Surgery +17
Kimiya Shimizu, Kazutaka Kamiya, Akihito Igarashi et al. · Medicine · 2016 · 124 citations · Full text
Medicine, Ophthalmology, Surgery +17