Journal of Perinatal Medicine · 2019 · 26 citations · 13 references
Abstract Objective To assess the feasibility and accuracy of point-of-care ultrasound (POCUS) in monitoring peripherally inserted central catheter (PICC) location in neonates by non-radiologist physicians. Methods A prospective cohort study compared PICC localization by ultrasound in neonates with a recent radiograph. The ultrasound exam was performed using a standardized protocol with 13–6 MHz linear and 8–4 MHz phased array transducers by a neonatal-perinatal fellow who was blinded to PICC location on the radiograph. Results Of the 30 neonates included, 96.6% (n = 29) were preterm, with 63.3% (n = 19) weighing <1500 g. Nighty-four percent (n = 94) of ultrasound scans matched the radiograph report. The protocol had a sensitivity of 0.97, specificity of 0.66 and positive predictive value of 0.98. Conclusion Limited ultrasound exams to monitor PICC position in neonates using a standardized protocol by non-radiologist physicians are feasible and accurate in a single ultrasound user. Further study in multiple providers is needed before widespread use.
13
Risk Factors for Peripherally Inserted Central Venous Catheter Complications in Children
Ketan Jumani, Sonali D. Advani, Nicholas G Reich et al. · JAMA Pediatrics · 2013 · 203 citations · Full text
Umbilical venous catheter position: evaluation by ultrasound
Natalia Simanovsky, Noa Ofek-Shlomai, Katya Rozovsky et al. · European Radiology · 2011 · 89 citations