Cancer Medicine · 2019 · 32 citations · 21 references
MedicineNuclear MedicineOncologyChemotherapyOncologic Nuclear MedicineRadionuclide TherapyBone Marrow EvaluationHematologic ToxicityOncologic Nuclear ImagingRadiation Dose MeasurementRadiation TherapyRadiation ToxicityAcute Hematologic ToxicityBone Marrow AssessmentDose-volume RelationshipHematologic Toxicity AssessmentHematologic Toxicity DiagnosisRadiation Dose AssessmentRadionuclide Uptake QuantificationVertebral Bodies
Abstract Background The purpose of the current study was to evaluate whether radiation dose‐volume metrics to technetium‐99m ( 99m Tc) sulfur colloid single‐photon emission tomography (SPET)‐defined active bone marrow (ABM) subregions can more accurately predict acute hematologic toxicity in locally advanced cervical cancer patients who receive chemoradiotherapy than conventional dosimetric parameters. Methods and materials Thirty‐nine patients with stage IB2‐III cervical cancer who underwent 99m Tc sulfur colloid SPET imaging before treatment with cisplatin‐based chemoradiation between January 2017 and March 2018 were analyzed. The total bone marrow (TBM) volume was defined as the external contours of all bones within the vertebral bodies from L4 to the coccyx, the pelvic bones, and the proximal femoral heads. The ABM volume was defined by SPET as the subregion of TBM with a nuclide uptake value greater than or equal to the mean total body nuclide uptake value. Student's t test was used to test for statistical significance between TBM and ABM dose‐volume metrics. Receiver operating characteristic (ROC) curves were generated to compare the predictors of grade 3 or higher (grade 3+) hematologic toxicity. Results The mean ABM‐V40 (23.22% ± 7.65%) and ABM‐V30 (45.28% ± 9.20%) were significantly lower than the mean TBM‐V40 (33.06% ± 6.72%) and TBM‐V30 (53.08% ± 7.77%), respectively ( t = 5.78, P = .001) ( t = 4.13, P = .001). The ABM volume (<387.5 cm 3 , AUC = 0.928, P = .001), ABM‐V30 (>46.5%, AUC = 0.875, P = .001), and ABM‐V40 (>23.5%, AUC = 0.858, P = .001) can predict the occurrence of grade 3+ hematologic toxicity. Among patients with an ABM volume < 387.5 cm 3 , 16/19 (84.2%) had grade 3+ hematologic toxicity compared to 3/20 (15%) with an ABM volume > 387.5 cm 3 . Conclusions The ABM volume (<387.5 cm 3 ) may be a better predictor of hematologic toxicity than conventional dose‐volume metrics, but this finding needs to be further evaluated.
21
Cancer incidence and mortality in China, 2014
Wanqing Chen, Kexin Sun, Rongshou Zheng et al. · Chinese Journal of Cancer Research · 2018 · 1.1K citations
Alfonso Dueñas‐González, Juan José Zarbá, Firuza D. Patel et al. · Journal of Clinical Oncology · 2011 · 479 citations · Full text
Sudeep Gupta, Amita Maheshwari, Pallavi Parab et al. · Journal of Clinical Oncology · 2018 · 466 citations