IEEE Transactions on Biomedical Circuits and Systems · 2019 · 36 citations · 28 references
EngineeringBiomedical EngineeringElectrical EngineeringBiomedical Signal ProcessingEmbedded SystemsEpilepsyElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographyElectroencephalography In EpilepsyNeural Recording TechnologiesWearable Health TechnologiesAmbulatory ElectroencephalographyDetection Latency OptimizationEeg-based Seizure DetectionElectroencephalography-based Seizure ClassificationEmbedded System IntegrationEpileptic Seizure DetectionSeizure DetectionVlsi Implementation
A patient-specific epilepsy diagnostic solution in the form of a wireless wearable ambulatory device is presented. First, the design, VLSI implementation, and experimental validation of a resource-optimized machine learning algorithm for epilepsy seizure detection are described. Next, the development of a mini-PCB that integrates a low-power wireless data transceiver and a programmable processor for hosting the seizure detection algorithm is discussed. The algorithm uses only EEG signals from the frontal lobe electrodes while yielding a seizure detection sensitivity and specificity competitive to the standard full EEG systems. The experimental validation of the algorithm VLSI implementation proves the possibility of conducting accurate seizure detection using quickly-mountable dry-electrode headsets without the need for uncomfortable/painful through-hair electrodes or adhesive gels. Details of design and optimization of the algorithm, the VLSI implementation, and the mini-PCB development are presented and resource optimization techniques are discussed. The optimized implementation is uploaded on a low-power Microsemi Igloo FPGA, requires 1237 logic elements, consumes 110 μW dynamic power, and yields a minimum detection latency of 10.2 μs. The measurement results from the FPGA implementation on data from 23 patients (198 seizures in total) shows a seizure detection sensitivity and specificity of 92.5% and 80.1%, respectively. Comparison to the state of the art is presented from system integration, the VLSI implementation, and the wireless communication perspectives.
28
PhysioBank, PhysioToolkit, and PhysioNet
Ary L. Goldberger, Luı́s A. Nunes Amaral, Leon Glass et al. · Circulation · 2000 · 14.5K citations · Full text
Long-term treatment with responsive brain stimulation in adults with refractory partial seizures
Gregory K. Bergey, Martha J. Morrell, Eli M. Mizrahi et al. · Neurology · 2015 · 642 citations · Full text
Medicine, Neurology, Neuroscience +17
EEG-based neonatal seizure detection with Support Vector Machines
Andriy Temko, Eoin Thomas, William P. Marnane et al. · Clinical Neurophysiology · 2010 · 339 citations · Full text