Circulation Cardiovascular Interventions · 2019 · 18 citations · 22 references
MedicineCardiologyCardiothoracic SurgeryClinical CardiologyInterventional CardiologyCardiac CatheterizationCardiovascular AssessmentCardiovascular ImagingCoronary AngiographyCoronary Artery DiseaseIschemic Heart DiseaseCoronary Flow AssessmentCoronary Flow Reserve AssessmentDistortionsFractional Flow Reserve ImagingInvasive Ischemia AssessmentMyocardial Flow ReservePressure DriftPressure Field Distortion
Background: Invasive fractional flow reserve (FFR INV ) is the standard technique for assessing myocardial ischemia. Pressure distortions and measurement location may influence FFR INV interpretation. We report a technique for performing invasive fractional flow reserve (FFR INV ) by minimizing pressure distortions and identifying the proper location to measure FFR INV . Methods: FFR INV recordings were obtained prospectively during manual hyperemic pullback in 100 normal and diseased coronary arteries with single stenosis, using 4 measurements from the terminal vessel, distal-to-the-lesion, proximal vessel, and guiding catheter. FFR INV profiles were developed by plotting FFR INV values ( y -axis) and site of measurement ( x -axis), stratified by stenosis severity. FFR INV ≤0.8 was considered positive for lesion-specific ischemia. Results: Erroneous FFR INV values were observed in 10% of vessels because of aortic pressure distortion and in 21% because of distal pressure drift; these were corrected by disengagement of the guiding catheter and re-equalization of distal pressure/aortic pressure, respectively. There were significant declines in FFR INV from the proximal to the terminal vessel in normal and stenotic coronary arteries ( P <0.001). The rate of positive FFR INV was 41% when measured from the terminal vessel and 20% when measured distal-to-the-lesion ( P <0.001); 41.5% of positive terminal measurements were reclassified to negative when measured distal-to-the-lesion. Measuring FFR INV 20 to 30 mm distal-to-the-lesion (rather than from the terminal vessel) can reduce errors in measurement and optimize the assessment of lesion-specific ischemia. Conclusions: Meticulous technique (disengagement of the guiding catheter, FFR INV pullback) is required to avoid erroneous FFR INV , which occur in 31% of vessels. Even with optimal technique, FFR INV values are influenced by stenosis severity and the site of pressure measurement. FFR INV values from the terminal vessel may overestimate lesion-specific ischemia, leading to unnecessary revascularization.
22
2014 ESC/EACTS Guidelines on myocardial revascularization
Philippe Kolh, Stephan Windecker, Fernándo Alfonso et al. · European Journal of Cardio-Thoracic Surgery · 2014 · 4.2K citations · Full text
Medicine, Cardiology, Surgery +14