Circulation Cardiovascular Imaging · 2019 · 53 citations · 24 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyAblation TherapyAtrial FibrillationEchocardiographic Hemodynamic AssessmentMitral RegurgitationMitral Valve DiseaseValvular Heart Disease ImagingEchocardiographic QuantificationIntraoperative Transesophageal EchocardiographyLeft Atrial RemodelingMitral Regurgitation Severity AssessmentMitral Valve AnatomyMitral Valve Leaflet AnatomyMitral Valve Regurgitation QuantificationMitral Valve Remodeling
Background: Mitral regurgitation is frequently complicated with atrial fibrillation without apparent organic changes in the leaflet, which occasionally improves after successful radiofrequency catheter ablation. We aimed to evaluate a possible geometric effect of radiofrequency catheter ablation on the mitral valve apparatus. Methods: Forty-three consecutive patients who underwent successful catheter ablation for persistent atrial fibrillation (maintaining sinus rhythm for 6 months after their procedure) were examined by serial real-time 3-dimensional transesophageal echocardiography before and 6 months after catheter ablation. Mitral valve complex geometry was measured using dedicated software for 3-dimensional transesophageal echocardiography. Results: Mitral valve apparatus showed significant reverse remodeling along with left atrial reverse remodeling 6 months after successful catheter ablation (50.5 [39.2–61.0] versus 36.4 [28.9–43.1] mL/m 2 ; P <0.001). The degree of mitral regurgitation decreased in a majority of patients (mitral regurgitation jet area; 1.83 [0.78–3.09] versus 0.77 [0.36–1.47] cm 2 ; P <0.001). Annular area significantly decreased (5.32±0.91 versus 4.73±0.76 cm 2 /m 2 ; P <0.001) in both anterior-posterior and medial-lateral directions. Mitral annular contraction significantly recovered after maintaining sinus rhythm for 6 months (7.51 [4.82–9.62]% versus 9.71 [6.27–13.85]%; P =0.008). There were no significant changes in tenting volume or tenting height (0.46 [0.27–0.89] versus 0.51 [0.32–0.72] mL/m 2 , P =0.744; 2.34 [1.75–3.48] versus 2.76 [1.99–3.08] mm/m 2 , P =0.717). The leaflet surface area also significantly decreased after catheter ablation (5.74 [5.01–6.33] versus 5.19 [4.63–5.64] cm 2 /m 2 ; P <0.001). Conclusions: Maintaining sinus rhythm after successful catheter ablation promotes reverse remodeling in the mitral valve apparatus and improves so-called atrial functional mitral regurgitation. The positive geometric effect of catheter ablation would be expected to be a possible contributor to better outcomes in patients with atrial fibrillation, in addition to the postprocedural freedom from rhythm disturbance.
24
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Helmut Baumgartner, Volkmar Falk, Jeroen J. Bax et al. · European Heart Journal · 2017 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +14
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Rick A. Nishimura, Catherine M Otto, Robert O. Bonow et al. · Circulation · 2014 · 2.9K citations
Medicine, Cardiology, Surgery +14
Catheter Ablation for Atrial Fibrillation with Heart Failure
Nassir Marrouche, Johannes Brachmann, Dietrich Andresen et al. · New England Journal of Medicine · 2018 · 2.4K citations