Water · 2019 · 10 citations · 39 references
EngineeringEnvironmental EngineeringWater Resources ManagementWastewater TreatmentWater Quality EngineeringWater TreatmentDrinking Water TreatmentGroundwater TreatmentMembrane FiltrationWastewater BiotreatmentCoagulationEnrichmentHumic Substance RemovalMicrofiltrationMicrofiltration MembranesMicrofiltration TreatmentSustainable Water SupplyWater Treatment Membranes
Synthetic solutions assimilating irrigated groundwater containing varying concentrations of humic acid (10 mg/L), saline (10–35 g/L) and metal agents (5–10 mg/L), were processed through a ceramic microfiltration membrane (Sterilox Ltd., 0.5 μm). This was done with enrichment schemes using polymeric coagulants (PDADMAC) applied to enhance the removal of the above-mentioned pollutants. The study was conducted with the scope of investigating the feasibility of sequential and hybrid coagulation and microfiltration as a method of choice for drinking water treatment. Membrane microfiltration is easily scalable into various arrangements, allowing versatility in operation and enrichment schemes, with a relatively lower cost which other treatment practices do not allow. The highest humic acid removal, 91.11% was achieved with hybrid coagulation.
39
Humic acid fouling during microfiltration
Wei Yuan · Journal of Membrane Science · 1999 · 428 citations
Engineering, Chemical Engineering, Environmental Engineering +10
Fundamental understanding of organic matter fouling of membranes
Gary Amy · Desalination · 2008 · 371 citations