Circulation · 2018 · 154 citations · 18 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyAortic StenosisAortic SurgeryAortic Valve DiseaseCardiac Valve SurgeryTranscatheter Aortic Valve ReplacementValvular Heart DiseaseAortic Valve EvaluationCardiovascular FailureDurability Of Bioprosthetic ValvesLong-term Efficacy AssessmentStructural Valve DeteriorationSymptomatic Severe Aortic StenosisValve Function Assessment
BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.
18
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Helmut Baumgartner, Volkmar Falk, Jeroen J. Bax et al. · European Heart Journal · 2017 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +14
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Martin B. Leon, Craig R. Smith, Michael J. Mack et al. · New England Journal of Medicine · 2016 · 5K citations · Full text
Medicine, Cardiology, Surgery +13
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
David Adams, Jeffrey J. Popma, Michael J. Reardon et al. · New England Journal of Medicine · 2014 · 2.9K citations · Full text
Medicine, Cardiology, Surgery +13
Michael J. Mack, Martin B. Leon, Craig R. Smith et al. · The Lancet · 2015 · 1.7K citations
Medicine, Cardiology, Surgery +11
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Martine Gilard, Hélène Eltchaninoff, Bernard Iung et al. · New England Journal of Medicine · 2012 · 1.2K citations · Full text
Medicine, Cardiology, Surgery +15