Ventilated Wall Claddings: Review, Field Performance, and Hygrothermal Modeling

John Straube, Graham Finch

2009 · 51 citations · 4 references

Concepts

Abstract

The use of ventilated air spaces behind claddings has been shown to influence the performance of some wall assemblies. Recently completed field and laboratory research has shown that cladding ventilation has the potential to increase drying and reduce wetting from absorptive claddings and sun-driven moisture. The use of one-dimensional hygrothermal simulation software has been well established for a wide range of wall and roof assemblies. However the use of such software has previously had a limited ability to accurately model the physics of enclosures with ventilated claddings. The most recent version of WUFI 4.1 (a widely used hygrothermal simulation package) has added the ability to model enclosure systems that incorporate embedded sources and sinks of moisture and heat. This capability can be used to model source effects such as air and rain leakage within a wall assembly or sinks such as drainage and ventilation. This paper investigates the use of the WUFI “source and sink” approach in a onedimensional model to simulate ventilation and rain leakage behind claddings. The simulation predictions are compared to the field performance of several different wall assemblies. Lessons learned on the use of this new model will be discussed. The impact of such effects as rain water leaks and cladding ventilation rates are also investigated. building science.com

References

4