Editor-in-Chief s Voice List of Authors is an Important Element in a Scientific Publication · 2018 · 25 citations · 13 references
MedicineSurgeryUrologyFemale UrologySurgical InstrumentationUrologic SurgeryMinimally Invasive Urologic SurgeryUreteral ImagingUreteral SurgeryUrinary Stone SurgeryUrinary Tract SurgeryUrologic InterventionsImage Quality MetricsManeuverabilityManeuverability TestingMinimally Invasive Ureteral SurgeryRadiographic Image QualityUreteral Stone SurgeryUreteroscopic SurgeryUreteroscopy
INTRODUCTION: The purpose of the present study was to clinically evaluate two new single-use Pusen ureteroscopes, one semirigid with a flexible tip (srURS) and one flexible (fURS). MATERIALS AND METHODS: During ten consecutive procedures (five srURS and five fURS), we subjectively evaluated on a scale from 0 (poor) to 10 (excellent), the scope's deflection, image quality, and maneuverability prior to, during and after the surgery. Patient demographics, complications with the devices, and troubleshooting were recorded. RESULTS: There were a total of ten patients, five of which were female while the other five were male. Mean age was 58.9 years. Seven patients had a single kidney stone with mean size of 9.6 mm (1.6-20 mm). Half of the patients were pre-stented. For the fURS, the preoperative image quality rating was 8.4 (8-10), compared with 6.8 (4-9) during surgery. The preoperative deflection rating was 9.6+ 0.9 (8-10), while during surgery this decreased to 8.0 (6-10) and to 6.0 (4-8) when using a laser fiber. The srURS had a preoperative image quality rating of 9.2 (8-10), which decreased to 7.6 (6-9) while using the scope. The deflection rating decreased from 9.4 (7-10) preoperatively to 7.0 (1-10) postoperatively, and a similar reduction was observed in the maneuverability rating, from 9.6 (8-10) to 7.4 (1-10). Ureteroscopy was considered as a standard in four of the fURS and three of the srURS procedures. The mean overall satisfaction rating was 6. CONCLUSIONS: The two new single-use ureteroscopes, one flexible and one semirigid, were considered to have allowed standard ureteroscopy in four and three out of the five procedures for each scope, respectively. The image quality, deflection, and maneuverability ratings decreased during the procedure for both scopes.
13
Classification of Surgical Complications
Daniel Dindo, Nicolas Demartines, Pierre-Alain Clavien · Annals of Surgery · 2004 · 30.9K citations · Full text
Medicine, Surgery, General Surgery +13
Current Standard Technique for Modern Flexible Ureteroscopy: Tips and Tricks
Guido Giusti, Silvia Proietti, Luca Villa et al. · European Urology · 2016 · 135 citations