MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyExternal Beam RadiotherapyImage-guided TherapyPositron Emission TomographyRadiation Imaging DetectorsRadiation Imaging SystemsDetector Linearity CorrectionDetector Timing ResolutionPet-computed TomographyPositron Emission Tomography-guided TherapySmall Animal Hybrid Imaging SystemsSmall Animal ImagingTime-of-flight PetTiming Resolution
Molecular imaging is becoming essential for precision targeted radiation therapy, yet progress is hindered from a lack of integrated imaging and treatment systems. We report the development of a prototype positron emission tomography (PET) scanner integrated into a commercial cone beam computed tomography (CBCT) based small animal irradiation system for molecular-image-guided, targeted external beam radiation therapy. The PET component consists of two rotating Hamamatsu time-of-flight PET modules positioned with a bore diameter of 101.6 mm and a radial field-of-view of 53.1 mm. The measured energy resolution after linearity correction at 511 KeV was 12.9% and the timing resolution was 283.6 ps. The measured spatial resolutions at the field-of-view center and 5 mm off the radial center were 2.6 mm x 2.6 mm x 1.6 mm and 2.6 mm x 2.6 mm x 2.7 mm respectively. <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">18</sup> F-Fluorodeoxyglucose-based PET imaging of a NEMA NU 4-2008 phantom resolved cylindrical volumes with diameters as small as 3 mm. To validate the system in-vivo, we performed <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">64</sup> Cu-DOTA-M5A PET and computed tomography (CT) imaging of carcinoembryonic antigen (CEA)-positive colorectal cancer in athymic nude mice and compared the results with a commercially available Siemens Inveon PET/CT system. The prototype PET system performed comparably to the Siemens system for identifying the location, size, and shape of tumors. Regions of heterogeneous <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">64</sup> Cu-DOTA-M5A uptake were observed. Using <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">64</sup> Cu-DOTA-M5A PET and CT images, a Monte Carlo-based radiation treatment plan was created to escalate the dose to the <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">64</sup> Cu-DOTA-M5A-based, highly active, biological target volume while largely sparing the normal tissue. Results demonstrate the feasibility of molecular-image-guided treatment plans using the prototype theranostic system.
17
Radiation detection and measurement
M.C. Scott · Annals of Nuclear Energy · 1980 · 1.2K citations
Analytic and iterative reconstruction algorithms in SPECT.
P.P. Bruyant · PubMed · 2002 · 323 citations