The Laryngoscope · 2019 · 11 citations · 7 references
MedicineOtolaryngologyAnesthesiaSleep MedicineSleep NeurologyAirway ManagementSleep Apnea CareSleep SurgerySleep-disordered BreathingCervical Nerve AnatomyCuff ElectrodesHypoglossal Nerve AnatomyObstructive Sleep Apnea TherapyObstructive Sleep Apnea TreatmentPolysomnography AnalysisSleep Apnea Outcome MeasurementSleepiness Measurement
Objectives/Hypothesis Upper airway stimulation (UAS) has demonstrated efficacy in the management of obstructive sleep apnea (OSA). Branches of the hypoglossal nerve that selectively activate tongue protrusor and stiffener muscles are included within the stimulation cuff electrode. The first cervical nerve (C1) is often also included to stimulate additional muscles contributing to tongue protrusion and stabilization. The purpose of this study was to determine whether inclusion of the C1 translates into treatment efficacy, decreased voltage requirement, and improved outcomes in patients utilizing UAS. Study Design Single‐center, retrospective cohort study. Methods One hundred fourteen patients who received a UAS implant at our institution and underwent posttreatment polysomnography were evaluated. Stimulation cuff electrodes in 87 patients included the C1; those in the remaining 27 patients did not include the C1. Demographic data, voltage data, and pre‐ and posttreatment apnea‐hypopnea index (AHI), O 2 nadir, and Epworth Sleepiness Scale (ESS) data were collected for all patients. Results There was no significant difference in stimulation voltage, or posttreatment AHI, O 2 nadir, and ESS between the two cohorts. Treatment success, as measured by posttreatment AHI < 20 with a 50% reduction, was similar regardless of C1 inclusion. The same was seen for the percent of patients with AHI < 15 and AHI < 5 after treatment. The distributions of age and body mass index, as well as pre‐treatment AHI, O 2 nadir, and ESS were also not significantly different between treatment groups. Conclusions The current study has demonstrated that inclusion of the C1 in the stimulation cuff electrode of the upper airway stimulator may not provide any additional benefit in therapy for OSA. Level of Evidence 4 Laryngoscope , 130:E382–E385, 2020
7
Upper-Airway Stimulation for Obstructive Sleep Apnea
Patrick J. Strollo, Ryan J. Soose, Joachim T. Maurer et al. · New England Journal of Medicine · 2014 · 1.2K citations · Full text
Medicine, Otolaryngology, Surgery +14
Upper Airway Stimulation for Obstructive Sleep Apnea: 5‐Year Outcomes
B. Tucker Woodson, Kingman P. Strohl, Ryan J. Soose et al. · Otolaryngology · 2018 · 332 citations · Full text
Medicine, Otolaryngology, Anesthesia +16
Three‐Year Outcomes of Cranial Nerve Stimulation for Obstructive Sleep Apnea
B. Tucker Woodson, Ryan J. Soose, M. Boyd Gillespie et al. · Otolaryngology · 2015 · 261 citations
Medicine, Otolaryngology, Anesthesia +16