Magnetic Resonance Imaging · 2019 · 91 citations · 37 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingMagnetic Resonance ImagingMedical Imaging3D Magnetic Resonance ImagingBland-altman PlotMagnetic ResonanceMagnetic Resonance PhysicsNuclear Magnetic Resonance RelaxometryQuantitative Magnetic Resonance ImagingQuantitative Relaxation MappingRepeatability
BACKGROUND: Previous methods for the quantification of brain tissue properties by magnetic resonance imaging were mainly based on two-dimensional acquisitions and were thus limited to a relatively low resolution in the slice direction compared to three-dimensional (3D) acquisitions. The 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) sequence may allow for simultaneous acquisition of relaxometry parameters in high spatial resolution. PURPOSE: To evaluate bias, linearity, and day-to-day repeatability of relaxometry parameters, as well as tissue fraction maps, acquired with 3D-QALAS. MATERIALS AND METHODS: Scan-rescan test of the 3D-QALAS sequence was performed on a 1.5-T scanner with the International Society for Magnetic Resonance in Medicine/National institute of Standards and Technology system phantom and 10 healthy volunteers (7 male, 3 female; mean age, 23.2 ± 3.6 years). Simple linear regression analysis, Bland-Altman plots, and intrasubject coefficients of variation (CV) were used to assess the reliability of 3D-QALAS sequence-derived parameters. The T1, T2, proton density (PD), and myelin volume fraction (MVF) of in vivo brain regions were compared with values obtained using the multidynamic multi-echo sequence. RESULTS: = 0.998, 0.998, and 0.960 for T1, T2, and PD, respectively) and high repeatability (mean CV of 1.2%, 2.8%, and 2.9% for T1, T2, and PD, respectively). The T1, T2, PD, and MVF values of in vivo brain regions obtained with 3D-QALAS were highly consistent within subjects, with mean intrasubject CVs of 0.5%, 0.5%, 0.4%, and 1.6% for the T1, T2, PD, and MVF values, respectively. CONCLUSION: 3D-QALAS enables reliable measurement of T1, T2, PD, and MVF values of the whole brain in high spatial resolution across a clinically-relevant dynamic range.
37
John C. Mazziotta, Arthur W. Toga, Alan C. Evans et al. · Philosophical Transactions of the Royal Society B Biological Sciences · 2001 · 2.4K citations · Full text
Medicine, Neurobiology, Neuroscience +15
Magnetic resonance fingerprinting
Dan Ma, Vikas Gulani, Nicole Seiberlich et al. · Nature · 2013 · 1.6K citations · Full text
Quantitative Magnetic Resonance Imaging of Human Brain Development: Ages 4–18
Jay N. Giedd, John W. Snell, Nicholas Lange et al. · Cerebral Cortex · 1996 · 1K citations · Full text