Circulation Heart Failure · 2019 · 14 citations · 40 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyCardiovascular DiseaseCardiovascular PhysiologyEndothelial DysfunctionHeart FailureIschemic Heart DiseaseMechanical Circulatory SupportEndothelial Cell PhysiologyEndothelial Dysfunction AssessmentEndothelializationLeft Ventricular Assist Device TherapyLeft Ventricular Assist DevicesVascular Endothelial FunctionVentricular Assist Device Support
Background: The coronary vasculature encounters a reduction in pulsatility after implementing durable continuous-flow left ventricular assist device (CF-LVAD) circulatory support. Evidence exists that appropriate pulsatility is required to maintain endothelial cell homeostasis. We hypothesized that coronary artery endothelial function would be impaired after CF-LVAD intervention. Methods and Results: Coronary arteries from patients with end-stage heart failure caused by ischemic cardiomyopathy (ICM; n=16) or non-ICM (n=22) cardiomyopathy were isolated from the left ventricular apical core, which was removed for the CF-LVAD implantation. In 11 of these patients, paired coronary arteries were obtained from an adjacent region of myocardium after the CF-LVAD intervention (n=6 ICM, 5 non-ICM). Vascular function was assessed ex vivo using isometric tension procedures in these patients and in 7 nonfailing donor controls. Maximal endothelium-dependent vasorelaxation to BK (bradykinin; 10 − 6 –10 − 10 M) was blunted ( P <0.05) in arteries from patients with ICM compared with non-ICM and donor controls, whereas responses to sodium nitroprusside (10 −4 –10 −9 M) were similar among the groups. Contrary to our hypothesis, vasorelaxation responses to BK and sodium nitroprusside were similar before and 219±37 days after CF-LVAD support. Of these patients, an exploratory subgroup analysis revealed that BK-induced coronary artery vasorelaxation was greater ( P <0.05) after (87±6%) versus before (54±14%) CF-LVAD intervention in ICM patients, whereas sodium nitroprusside–evoked responses were similar. Conclusions: Coronary artery endothelial function is not impaired by durable CF-LVAD support and in ICM patients appears to be improved. Investigating coronary endothelial function using in vivo approaches in a larger patient population is warranted.
40
Roberto M. Lang, Michelle Bierig, Richard B. Devereux et al. · Journal of the American Society of Echocardiography · 2005 · 11.3K citations
Cardiac Improvement During Mechanical Circulatory Support
Simon Maybaum, Donna Mancini, Steve Xydas et al. · Circulation · 2007 · 399 citations
Medicine, Cardiology, Surgery +17