Smaller injection volumes of a higher concentration moxifloxacin resulted in less accuracy and less precision in the delivered dose (0.05 mL, P = .005; 0.10 mL, P = .03); however, the clinical significance of this might vary. Injection of 0.5%/0.1 mL and flushing with 0.15%/0.5 mL of moxifloxacin would provide similar drug AC residence times according to the model. Flushing provided more consistent AC concentrations with differing AC volumes.