Journal of Oral Implantology · 2019 · 12 citations · 36 references
DentistryImplant DentistryProsthodonticsDentoalveolar SurgeryImplant ProsthodonticsImplant SurgeryBone Quality AssessmentLaser SurgeryDental Laser ApplicationsImplant StabilityMandibular Implant-supported OverdenturesMandibular Overdentures LoadingMarginal Bone Loss EvaluationMarginal Bone PreservationMarginal Bone StabilityOverdenture Retention
The researchers investigated the influence of low-level laser irradiation (LLLI) on implant stability and marginal bone of small-diameter implants retaining mandibular overdentures in patients with moderately controlled diabetes. Twenty patients (mean age = 59.32 ± 4.1 years) with moderately controlled diabetes mellitus (glycated hemoglobin A1c [HbA1c] = 8.1%–10.0 %) were rehabilitated by maxillary and mandibular conventional dentures. Two small-diameter implants (3 × 12 mm) were inserted in the canine areas of the mandible and immediately loaded by mandibular dentures. In a split-mouth design, LLLI was applied to 1 of the 2 implants in a random order (study group [SG]); the other implant was left as a control (control group [CG]). For each patient, gallium aluminum-arsenide diode low-level laser (940-nm wavelength, 0.50 ± 2 mW output power, 0.004 cm 2 spot size; Epic, Biolase, Inc, San Clemente, Calif) was applied around each implant with total delivered energy of 90 J (equally divided by 6 irradiation points) in 3 sessions. The application was done immediately after implant insertion, 3 days and 1 week after surgery. Implant stability (measured by Periotest) and marginal bone loss (MBL; measured by cone beam computerized tomography) were evaluated at implant loading (T1), 6 months (T6), and 12 months (T12). One implant failed in the CG and no failures occurred in the SG, resulting in 95% and 100% survival rates, respectively. The SG recorded higher Periotest values than the CG at all observation times. However, the difference was significant ( P = .039) at T6 only. The SG recorded lower MBL values than the CG. No difference in MBL was detected between groups or peri-implant sites (mesial, distal, buccal, and lingual) at T6 and T12. Within the limits of this study, LLLI had no effect on marginal bone around immediately loaded small-diameter implants retaining overdentures in patients with moderately controlled diabetes. However, it was beneficial in improving implant stability 6 months after overdenture insertion.
36
Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.
R Adell, Bengt O. Eriksson, Ulf Lekholm et al. · PubMed · 1990 · 1.9K citations
Persistent Acute Inflammation at the Implant-Abutment Interface
Nina Broggini, Linda M. McManus, Joachim S. Hermann et al. · Journal of Dental Research · 2003 · 422 citations
Morbidity of harvesting of chin grafts: a prospective study
Emeka Nkenke, Stefan Schultze–Mosgau, Frank Kloss et al. · Clinical Oral Implants Research · 2001 · 344 citations
Dentistry, Oral Surgery, Anesthesia +13