Ultrasound‐Guided Umbilical Venous Catheter Insertion With Alignment of the Umbilical Vein and Ductus Venosus

Makoto Kishigami, Tomoyuki Shimokaze, Masahiro Enomoto, Jun Shibasaki, Katsuaki Toyoshima

Journal of Ultrasound in Medicine · 2019 · 39 citations · 11 references

Concepts

Abstract

Previous studies have highlighted the importance of confirming the position of an umbilical venous catheter (UVC) tip by an ultrasound (US) examination. However, methods for preventing insertion into the portal circulation under US guidance have not yet been established. We report 15 cases in which a UVC was successfully passed through the ductus venosus by compressing the upper abdomen near the portal sinus of the liver to align the umbilical vein and ductus venosus under US guidance. The UVC was inserted into the correct position in 14 of the 15 neonates (93%) without complications.