Medicine & Science in Sports & Exercise · 2019 · 112 citations · 40 references
MedicineKinesiologySports MedicineDiagnostic ImagingUltrasonographyUltrasoundMusculoskeletal AssessmentMusculoskeletal ImagingMusculoskeletal UltrasonographyMusculoskeletal UltrasoundScanning TechniquesUltrasound ImagingBiceps Tendon UltrasoundFascicle LengthMuscle Fascicle LengthMuscle ThicknessTrigonometric FormUltrasound Limb Length MeasurementUltrasound Muscle ImagingUltrasound-based Muscle Assessment
PURPOSE: This study aimed to compare biceps femoris long head (BFlh) fascicle length (Lf) obtained with different ultrasound-based approaches: 1) single ultrasound images and linear Lf extrapolation, 2) single ultrasound images and one of two different trigonometric equations (termed equations A and B), and 3) extended field of view (EFOV) ultrasound images. METHODS: Thirty-seven elite alpine skiers (21.7 ± 2.8 yr) without a previous history of hamstring strain injury were tested. Single ultrasound images were collected with a 5-cm linear transducer from BFlh at 50% femur length and were compared with whole muscle scans acquired by EFOV ultrasound. RESULTS: The intrasession reliability (intraclass correlation coefficient [ICC3,k]) of Lf measurements was very high for both single ultrasound images (i.e., Lf estimated by linear extrapolation; ICC3,k = 0.96-0.99, SEM = 0.18 cm) and EFOV scans (ICC3,k = 0.91-0.98, SEM = 0.19 cm). Although extrapolation methods showed cases of Lf overestimation and underestimation when compared with EFOV scans, mean Lf measured from EFOV scans (8.07 ± 1.36 cm) was significantly shorter than Lf estimated by trigonometric equations A (9.98 ± 2.12 cm, P < 0.01) and B (8.57 ± 1.59 cm, P = 0.03), but not significantly different from Lf estimated with manual linear extrapolation (8.40 ± 1.68 cm, P = 0.13). Bland-Altman analyses revealed mean differences in Lf obtained from EFOV scans and those estimated from equation A, equation B, and manual linear extrapolation of 1.91 ± 2.1, 0.50 ± 1.0, and 0.33 ± 1.0 cm, respectively. CONCLUSIONS: The typical extrapolation methods used for estimating Lf from single ultrasound images are reliable within the same session, but not accurate for estimating BFlh Lf at rest with a 5-cm field of view. We recommend that EFOV scans are implemented to accurately determine intervention-related Lf changes in BFlh.
40
Muscle Architecture of the Human Lower Limb
Thomas L. Wickiewicz, Roland R. Roy, P. L. Powell et al. · Clinical Orthopaedics and Related Research · 1983 · 928 citations
Medicine, Anatomy, Physiology +17
Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Samuel R. Ward, Carolyn M. Eng, Laura Smallwood et al. · Clinical Orthopaedics and Related Research · 2008 · 690 citations · Full text
Medicine, Anatomy, Physiology +17
Muscle fiber architecture in the human lower limb
James A. Friederich, Richard A. Brand · Journal of Biomechanics · 1990 · 559 citations
Medicine, Anatomy, Physiology +13