AIP conference proceedings · 2019 · 12 citations · 11 references
EngineeringMechanical EngineeringComputational Heat TransferHeat TransferThermal AnalysisEnergy ConversionReceiver SystemsThermal DesignBlade DesignConvectionMolten Salt ReactorsReceiver DesignTechnoeconomic AnalysisThermal-hydraulic DesignTransmitter Design
A bladed receiver design concept is presented which offers a >2% increase in overall receiver efficiency after considering spillage, reflection, emission and convection losses, based on an integrated optical-thermal model, for a design where the working fluid is conventional molten salt operating in the standard 290–565°C temperature range. A novel testing methodology is described, using air and water to test the receiver when molten salt facilities are not available. Technoeconomic analysis shows that the receiver could achieve a 4 AUD/MWhe saving in levelised cost of energy, but only if the bladed receiver design can be implemented at no additional cost.
11
Experimental testing of a high-flux cavity receiver
John Pye, Joe Coventry, Felix Venn et al. · AIP conference proceedings · 2017 · 31 citations · Full text
Engineering, Electrical Engineering, Mechanical Engineering +13