Towards testing of a second-generation bladed receiver

John Pye, Ehsan Abbasi, Maziar Arjomandi, Joe Coventry, Farzin Ghanadi, Graham Hughes, Jin Soo Kim, Li Ma, Ali Shirazi, Juan F. Torres,

AIP conference proceedings · 2019 · 12 citations · 11 references

DOIFull text

Open access

Concepts

Abstract

A bladed receiver design concept is presented which offers a >2% increase in overall receiver efficiency after considering spillage, reflection, emission and convection losses, based on an integrated optical-thermal model, for a design where the working fluid is conventional molten salt operating in the standard 290–565°C temperature range. A novel testing methodology is described, using air and water to test the receiver when molten salt facilities are not available. Technoeconomic analysis shows that the receiver could achieve a 4 AUD/MWhe saving in levelised cost of energy, but only if the bladed receiver design can be implemented at no additional cost.

References

11