Journal of the Formosan Medical Association · 2019 · 50 citations · 14 references
MedicineDental Biomaterials ScienceBone GraftingImplant SurgeryPeri-implant DiseasesBone Graft SubstitutesBone MechanicsOsteogenesisPeri-implantitis TherapySynthetic Bone Substitutes3D-printed ImplantsBiomechanics Of Dental ImplantsBone Defect MorphometryDental ImplantsMicro-computed Tomography EvaluationNew Bone FormationOsseointegrationPorous Titanium Implants
Alveolar bone loss following peri-implantitis remains a clinical challenge. We aimed to design a novel bioactive dental implant to accommodate the large bone defect caused by removal of previously failed implant. Bio-ActiveITRI dental implant was manufactured with laser-sintered additive 3D printing technique. A 7.5 mm diameter × 7.0 mm depth osteotomy defect was created at the lateral aspect of distal femur of 20 New Zealand white rabbits to simulate the bony defect after removal of failed dental implant. One side of distal femurs was randomly selected for the commercially pure titanium NobelActive™ implant (control group) and the other side with Bio-ActiveITRI Ti6Al4V porous dental implant (ITRI group). Animals were sacrificed at 4, 8 and 12 weeks after the implants' insertion. The samples were processed for gross morphological analysis, radiographic examination, micro-CT evaluation, and mechanical testing. In histomorphometrical evaluation and micro-CT analysis, active new bone formation and good osseointegration within the ITRI implants were observed at the bone gap surrounding the dental implants. The biomechanical parameters in the Bio-ActiveITRI dental implants were significantly higher than those of the commercially control samples. For the Bio-ActiveITRI dental implants, the trabecular thickness decreased, while the trabecular separation and total porosity increased from the prescribed 1-month to 3-month time points; reflecting the natural remodeling of surrounding bony tissue in the Bio-ActiveITRI dental implants. The novel porous structured Bio-ActiveITRI dental implants may have a great potential for the prosthetic reconstruction where bone support is compromised after removal of a previously failed implant.
14
The jumping distance revisited
Daniele Botticelli, Tord Berglundh, Daniel Buser et al. · Clinical Oral Implants Research · 2003 · 250 citations
Dentistry, Dental Biomaterials Science, Implant Dentistry +10
Fei Yang, Chen Chen, Qianrong Zhou et al. · Scientific Reports · 2017 · 98 citations · Full text
Dentistry, Dental Biomaterials Science, Dental Materials Science +17