Experimental and modelling evaluations of sulfide formation in a mega-sized deep tunnel sewer system and implications for sewer management

Zhensheng Liang, Jianliang Sun, Henry Chau, Echo Leong, Di Wu, Guanghao Chen, Feng Jiang

Environment International · 2019 · 42 citations · 38 references

DOIFull text

Open access

Concepts

Abstract

= 0.61), but the linear relationship with the sewer diameter was weak. The sulfide production rate increased with increasing temperature (12 °C-32 °C) by 3.5 times, and it only decreased by 50% when the sulfate concentration decreased from 309 to 17 mg S/L, indicating that serious sulfide pollution could still happen in the sewers with a low concertation of sulfate in sewage. Increasing the organic levels in sewage would also promote the sulfide production in sewers. The flowrate would not influence the sulfide production rate significantly, but a storm event could remarkably reduce the sulfide production in rainy days. The findings unveil the potential serious sulfide problems in the mega-sized deep tunnel sewer systems, which are being increasingly constructed in China and other countries. To mitigate the odor and corrosion problems in the deep tunnel sewer systems, the sulfide control strategies should be considered during the sewer design and management.