Annuloplasty ring dehiscence after mitral valve repair: incidence, localization and reoperation

Thilo Noack, Philipp Kiefer, Nina Vivell, Franz Sieg, Mateo Marín-Cuartas, Sergey Leontyev, David Holzhey, Jens Garbade, Bettina Pfannmueller, Piroze Davierwala,

European Journal of Cardio-Thoracic Surgery · 2019 · 24 citations · 18 references

DOIFull text

Open access

Abstract

Annuloplasty ring dehiscence is clinically less common, localized more frequently on the posterior annulus and occurs mostly acutely or early after MV repair. MV reoperation can be performed safely in such patients.

References

18