Journal of Instrumentation · 2015 · 11 citations · 4 references
EngineeringElectrical EngineeringNuclear EngineeringNuclear InstrumentationRadiation DetectionRadiation MeasurementAccelerator PhysicsCharged Particle DetectionRadiation ResistanceResistance MeasurementHigh-energy Particle RadiationRate CapabilityResistance ComponentsResistive Plate ChambersResistivityResistivity MeasurementTotal ResistanceTotal Resistance Curves
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. This paper reports on measurements of the performance of three different glass RPC designs featuring a different total resistance of the resistive plates. The measurements were performed with 120 GeV protons at varying beam intensities.
4
Measurement of the rate capability of Resistive Plate Chambers
B. Bilki, James Butler, E. N. May et al. · Journal of Instrumentation · 2009 · 53 citations · Full text
Resistive Plate Chambers for hadron calorimetry: Tests with analog readout
G. Drake, José Repond, D. G. Underwood et al. · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2007 · 39 citations
Engineering, Electrical Engineering, Nuclear Engineering +12
Environmental dependence of the performance of resistive plate chambers
Qingmin Zhang, B. Bilki, James Butler et al. · Journal of Instrumentation · 2010 · 21 citations · Full text