bioRxiv (Cold Spring Harbor Laboratory) · 2019 · 11 citations · 43 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingElectrophysiologyNeural EngineeringBiophysical Data AnalysisBiopotential MeasurementComputational ElectrophysiologyCurrent DistributionElectrophysiological ModelingNeural Signal AcquisitionBiopotential Signal Quality AssessmentCurrent DensityCurrent Density DistributionCurrent EstimationElectrophysiological Parameter EstimationElectrophysiological RecordingsExperimental Data CollectionInterpreting Experimental Data
Abstract Interpretation of the extracellular recordings can be difficult due to the long range of electric field but can be facilitated by estimating the density of current sources (CSD). Here we introduce kCSD-python , an open Python package implementing Kernel Current Source Density (kCSD) method, and introduce several new techniques to facilitate CSD analysis of experimental data and interpretation of the results. We investigate the limitations imposed by noise and assumptions in the method itself. kCSD-python allows CSD estimation for arbitrary distribution of electrodes in 1D, 2D, and 3D, assuming distributions of sources in tissue, a slice, or in a single cell, and includes a range of diagnostic aids. We demonstrate its features in a Jupyter notebook tutorial to facilitate uptake by the community.
43
N. Aronszajn · Transactions of the American Mathematical Society · 1950 · 5.4K citations · Full text
Fully integrated silicon probes for high-density recording of neural activity