Physica Medica · 2019 · 17 citations · 20 references
MedicinePediatricsRadiologyDiagnostic RadiologyPediatric RadiologyRadiation DosimetryImage QualityImage Quality AssessmentPatient Dose OptimizationPhantom DosimetryRadiation Dose MeasurementRadiation Exposure In ChildhoodImage Acquisition ParametersOptimization Of Scan ParametersOptimization Of X-ray ExaminationsRadiation Dose AssessmentRadiation Dose OptimizationRadiographic Exposure ParametersRadiographic Image QualityX-ray Imaging Parameters
OBJECTIVE: To investigate the optimum pelvis X-ray acquisition factors for a 10-year-old child. Secondly, to evaluate the impact of each acquisition factor on image quality (IQ) and radiation dose. METHOD: Images were acquired using a pelvis phantom and a range of acquisition parameters; e.g. tube potential, additional filtration and source-to-image distance (SID). Automatic exposure control (AEC) was used with two orientations (head towards/away from two outer chambers) and three different chamber selections. Visual IQ was evaluated using relative and absolute-VGA methods. Radiation doses were measured by placing a dosimeter on the anterior surface of the phantom. Regression analysis was used to determine optimum parameters. RESULTS: The optimised technique (178.8 µGy), with diagnostic IQ, was with 89kVp, 130 cm SID and with 1 mm Al + 0.1 mm Cu filtration. This technique was with the head towards the two outer AEC chambers. Regression analysis showed that SID had the lowest impact on IQ (β = 0.002 95% CI -0.001 to 0.005) and dose (β = -0.96 95% CI -0.40 to -1.53). The impact of filtration on dose (β = -76.24 95% CI -86.76 to -85.72) was higher than tube potential (β = -13.44 95% CI -14.34 to -12.53). The following impact ratios were higher on IQ than radiation dose: filtration/kVp; 11.28 times, filtration/SID; 7.01 times and kVp/SID; 0.62 times. CONCLUSION: Optimised parameters were identified as 89 kVp, 130 cm SID and with 1 mm Al + 0.1 mm Cu additional filtration. Regression analysis demonstrated that filtration and tube potential had the greatest effect on radiation dose and IQ, respectively.
20
Fundamentals of Biostatistics.
Annals of Internal Medicine · 1969 · 4.6K citations
Discovering statistics using R
Choice Reviews Online · 2012 · 2.6K citations
Evaluating imaging systems: practical applications
Magnus Båth · Radiation Protection Dosimetry · 2010 · 97 citations
Optimisation in general radiography
CJ Martin · Biomedical Imaging and Intervention Journal · 2007 · 82 citations · Full text