European Radiology Experimental · 2019 · 22 citations · 28 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingChest RadiographyChest RadiologyComputed TomographyMedical ImagingPulmonary ImagingRadiographic ImagingChest Radiography FindingsDark-field ImagingLung Parenchymal ImagingMulti-slice Computed TomographyRadiographic Image QualityScatter PlotsSignalsVoltage
BACKGROUND: Although x-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs. Therefore, in this work, a reader study on nine post-mortem human chest x-ray dark-field radiographs was performed to evaluate dark-field signal strength in the lungs, intraobserver and interobserver agreement, and image quality and to correlate with findings of conventional x-ray and CT. METHODS: In this prospective work, chest x-ray dark-field radiography with a tube voltage of 70 kVp was performed post-mortem on nine humans (3 females, 6 males, age range 52-88 years). Visual quantification of dark-field and transmission signals in the lungs was performed by three radiologists. Results were compared to findings on conventional x-rays and 256-slice computed tomography. Image quality was evaluated. For ordinal data, median, range, and dot plots with medians and 95% confidence intervals are presented; intraobserver and interobserver agreement were determined using weighted Cohen κ. RESULTS: Dark-field signal grading showed significant differences between upper and middle (p = 0.004-0.016, readers 1-3) as well as upper and lower zones (p = 0.004-0.016, readers 1-2). Median transmission grading was indifferent between all lung regions. Intraobserver and interobserver agreements were substantial to almost perfect for grading of both dark-field (κ = 0.793-0.971 and κ = 0.828-0.893) and transmission images (κ = 0.790-0.918 and κ = 0.700-0.772). Pulmonary infiltrates correlated with areas of reduced dark-field signal. Image quality was rated good for dark-field images. CONCLUSIONS: Chest x-ray dark-field images provide information of the lungs complementary to conventional x-ray and allow reliable visual quantification of dark-field signal strength.
28
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Hard-X-ray dark-field imaging using a grating interferometer
Franz Pfeiffer, Martin Bech, Oliver Bunk et al. · Nature Materials · 2008 · 1.1K citations
Natural Sciences, Physics, Radiology +14
U. Bonse, Michael Hart · Applied Physics Letters · 1965 · 1K citations
Recent Advances in X-ray Phase Imaging
Atsushi Momose · Japanese Journal of Applied Physics · 2005 · 548 citations · Full text