Journal of NeuroInterventional Surgery · 2019 · 14 citations · 26 references
MedicineNeurologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAcute Ischemic StrokeMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingStrokeStroke ImagingThrombosisAcute Ischemic Stroke TreatmentAcute Stroke ImagingGradient Echo SequencesNatural Signal SaturationNeuroimaging Of Ischemic StrokeStroke NeuroimagingSusceptibility-weighted ImagingThrombus Characterization
BACKGROUND: Thrombus composition has the potential to affect acute ischemic stroke (AIS) treatment. OBJECTIVE: To evaluate in an in vitro test the correlation of clot composition, especially erythrocytes (red blood cells (RBCs)), with the variation of signal intensity ratio (SIR) obtained with MRI sequences used for AIS, and qualification of the susceptibility vessel sign effect using clot analogs. MATERIALS AND METHODS: Nine ovine clots were fixed in a gelatin-manganese solution and studied by MRI (T2GE, T2-weighted gradient echo; SWI, susceptibility-weighted imaging; FLAIR, fluid attenuated inversion recovery). RBC concentration was estimated using regression models (SLR, single linear regression; MLR, multiple linear regression; RF, random Forest; and ANN, artificial neural networking), which combined the SIR-histology relationship of three MRI sequences. RESULTS: Negative correlation was found between SIR and RBC concentration. T2GE SWI could not statistically distinguish clots with RBC content >54% and <23%. SLR was applied only to FLAIR images since T2GE and SWI demonstrated signal saturation. All four regression models showed a correlation between MRI and histology: SLR=0.981; MLR=0.986; RF=0.994, and ANN=0.971. One unknown clot was studied and agreement between SIR and histological analyses was found in all models. CONCLUSIONS: We presented a method to quantify RBC concentration in clot analogs, combining SWI, T2GE, and FLAIR. This in vitro study has some limitations, so clot collection after thrombectomy with simultaneous imaging analysis is necessary to validate this model.
26
NMR relaxation times in the human brain at 3.0 tesla
Janaka Wansapura, Scott K. Holland, R. Scott Dunn et al. · Journal of Magnetic Resonance Imaging · 1999 · 846 citations · Full text
Medicine, Neuroscience, Radiology +17
Non-invasive assessment of hepatic iron stores by MRI
Y. Gandon, Damien Olivié, Dominique Guyader et al. · The Lancet · 2004 · 666 citations
CT and MRI Early Vessel Signs Reflect Clot Composition in Acute Stroke
David S. Liebeskind, Nerses Sanossian, William H. Yong et al. · Stroke · 2011 · 505 citations · Full text