Experimental study and parametric analysis of SO<sub>2</sub> capture in limestone fixed bed reactor

Christos D Bontzolis, Maria K Petraki, Dimitrios Nikolaos Spartinos

Journal of Chemical Technology & Biotechnology · 2019 · 13 citations · 39 references

Concepts

Abstract

Abstract BACKGROUND The use of absorbents, based on calcium, for the reduction of sulfur dioxide (SO 2 ) emissions from power plants has been studied for the last 90 years. The present work is part of a research project, which aims at the development of a fixed and a moving bed limestone filter. A filter is placed after the burning, in order to capture SO 2 from the flue gases of pulverized lignite combustors. An experimental study and a parametric analysis in a limestone and lignite fixed bed reactor for SO 2 capture were conducted in previous works. RESULTS This work studies experimentally the SO 2 capture by analyzing the following parameters: inlet mole fraction of SO 2 , inlet mole fraction of O 2 , volumetric flow rate, average temperature in bed, type of calcium carbonate (CaCO 3 ) and length of the solid bed. Under specific circumstances, conversion of SO 2 values were found to be greater than 0.99 in the gas outlet for more than 110 min. CONCLUSION Useful conclusions are drawn regarding the behavior of a fixed bed reactor in different conditions. The results highlight the importance of technological interest in the dry process for SO 2 capture. © 2019 Society of Chemical Industry

References

39