EngineeringBioengineeringBiomedical EngineeringBiomaterialsDrug DeliveryTissue EngineeringAngiogenesisDrug Delivery BiomaterialsGrowth Factor DeliveryGrowth Factor Delivery SystemsPolymeric Drug Delivery SystemsTissue Engineering ScaffoldsAngiogenic Delivery SystemsLocal Sustained Release Delivery SystemsMicrosphere Delivery SystemsMicrospheresSynthetic ScaffoldsSynthetic Tissue ScaffoldsVascular Endothelial Growth FactorVascularization
-[PLLA])-based multiblock copolymers with different PEG content and PEG molecular weight were used to prepare the microspheres. Loading of the microspheres was established by a solvent evaporation-based membrane emulsification method. The resulting VEGF-loaded microspheres had average sizes of 40-50 μm and a narrow size distribution. Optimized formulations of a 50:50 blend of the two multiblock copolymers had an average VEGF loading of 0.79 ± 0.09%, representing a high average VEGF loading efficiency of 78 ± 16%. These microspheres released VEGF continuously over 4 weeks in phosphate-buffered saline pH 7.4 at 37 °C. This release profile was preserved after repeated and long-term storage at -20 °C for up to 9 months, thereby demonstrating excellent storage stability. VEGF release was governed by diffusion through the water-filled polymer matrix, depending on PEG molecular weight and PEG content of the polymers. The bioactivity of the released VEGF was retained within the experimental error in the 4-week release window, as demonstrated using a human umbilical vein endothelial cells proliferation assay. Thus, the microspheres prepared in this study are suitable for embedment in polymeric scaffolds with the aim of promoting their functional vascularization.