Journal of the Brazilian Chemical Society · 2019 · 11 citations · 0 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryElectrochemistryNanomaterialsElectroanalytical ChemistryElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsElectrode MaterialsMagnetic SensorsElectrochemical MeasurementsEnergy Dispersive X-ray SpectroscopyMagnetic NanoparticlesMolecularly Imprinted MaterialsMolecularly Imprinted Polymer SensorsMolecularly Imprinted PolymersSquare-wave VoltammetryVoltammetry
A polyurethane composite electrode modified with magnetic nanoparticles (mag; Fe 3 O 4 ) coated with molecularly imprinted polymers (MIPs) was developed for the electrochemical determination of estradiol valerate. Chemical and morphological analyses of the mag-MIP were performed using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), with the aim of characterizing this new material. The efficiency of adsorption of estradiol valerate by the mag-MIP was tested in binding experiments using an electrochemical method. For this, different electrodes (mag-MIP / graphite-epoxy composite (GEC), mag-non-imprinted polymer (NIP) / GEC, mag / GEC, and GEC) were evaluated by square-wave voltammetry (SWV). After 10 min at open circuit potential, increases in the current signal of 1.9, 2.1, and 3.0 times were obtained, comparing the electrochemical response of the mag-MIP / GEC sensor to the mag-NIP / GEC, mag / GEC, and GEC sensors, respectively. Under optimized conditions, the mag-MIP / GEC showed a linear concentration range for estradiol valerate of 5.0 10 -7 to 7.5 10 -4 mol L -1 and a limit of detection of 1.0 10 -8 mol L -1 . The proposed sensor was applied in the analysis of pharmaceutical, human urine, and river water samples. The recovery values determined using high performance liquid chromatography (HPLC)-UV and the electrochemical method were in agreement and were near 100%, demonstrating the reliability of the proposed method.