Scientific Reports · 2019 · 14 citations · 32 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAortic ImagingCardiovascular AssessmentCardiovascular ImagingHemodynamicsVascular Imaging4D Flow Magnetic Resonance ImagingAortic Flow ImagingBlood Flow MeasurementEddy Current CorrectionFlow Velocity MeasurementsMagnetic Resonance Flow ImagingMagnetic Resonance Flow QuantificationScan Time Reduction
To compare two broadly used 4D-flow- with a 2D-flow-sequence in healthy volunteers, regarding absolute flow parameters, image quality (IQ), and eddy current correction (ECC). Forty volunteers (42 ± 11.8 years, 22 females) were examined with a 3T scanner. Thoracic aortic flow was assessed using a 3D-T2w-SPACE-STIR-sequence for morphology and two accelerated 4D-flow sequences for comparison, one with k-t undersampling and one with standard GRAPPA parallel-imaging. 2D-flow was used as reference standard. The custom-made software tool Bloodline enabled flow measurements for all analyses at the same location. Quantitative flow analyses were performed with and without ECC. One reader assessed pathline IQ (IQ-PATH) and occurrence of motion artefacts (IQ-ART) on a 3-point grading scale, the higher the better. k-t GRAPPA allowed a significant mean scan time reduction of 46% (17:56 ± 5:26 min vs. 10:40 ± 3:15 min) and provided significantly fewer motion artefacts than standard GRAPPA (IQ-ART 1.57 ± 0.55 vs. 0.84 ± 0.48; p < 0.001). Neither 4D-flow sequence significantly differed in flow volume nor peak velocity results with or without ECC. Nevertheless, the correlation between both 4D-flow sequences and 2D-flow was better with ECC; the k-t GRAPPA sequence performed best (R = 0.96 vs. 0.90). k-t GRAPPA 4D-flow was not inferior to a standard GRAPPA-sequence, showed fewer artefacts, comparable IQ and was almost two-fold faster.
32
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text
The Global Economic Burden of Noncommunicable Diseases
David E. Bloom, Elizabeth Cafiero, Eva Jané‐Llopis et al. · WU Research · 2012 · 2K citations · Full text
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Joachim Lotz, Christian Meier, Andreas Leppert et al. · Radiographics · 2002 · 659 citations
Medicine, Cardiology, Radiology +16
Time‐resolved three‐dimensional phase‐contrast MRI
Michael Markl, Frandics P. Chan, Marcus T. Alley et al. · Journal of Magnetic Resonance Imaging · 2003 · 395 citations