Journal of Applied Clinical Medical Physics · 2019 · 10 citations · 36 references
MedicineBioengineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingMagnetic Resonance ImagingConfidence Intervals For Correlation CoefficientsCorrelationMagnetic ResonanceMagnetic Resonance PhysicsSolid Phantoms
The T1 value of pure water, which is often used as a phantom to simulate cerebrospinal fluid, is significantly different from that of in-vivo cerebrospinal fluid. The purpose of this study was to develop a phantom with a T1 value equivalent to that of in-vivo cerebrospinal fluid under examination room temperature (23°C-25°C). In this study, 1.5 and 3.0 T magnetic resonance imaging scanners were used. We examined the signal intensity change in relation to pure water temperature, the T1 values of acetone-diluted solutions (0-100 v/v%, in 10 steps), and the correlation coefficients obtained from volunteers and the prepared phantoms. The T1 value was close to the value reported in the literature for cerebrospinal fluid when the acetone-diluted solution was 70 v/v% or higher at scan room temperature. The value at that time was 3532.81-4704.57 ms at 1.5 T and it ranged from 4052.41 to 5701.61 ms at 3.0 T. The highest correlation with the values obtained from the volunteers was r = 0.993 with pure acetone at 1.5 T and r = 0.991 with acetone 90 v/v% at 3.0 T. The relative error of the best phantom-volunteer match was 32.61 (%) ± 6.71 at 1.5 T and 46.67 (%) ± 4.31 at 3.0 T. The T1 value measured by the null point method did not detect a significant difference between in vivo CSF and acetone 100 v/v% at 1.5 T and acetone 90 v/v% at 3.0 T. The T1 value of cerebrospinal fluid in the living body at scan room temperature was reproduced with acetone. The optimum concentration of acetone for cerebrospinal-fluid reproduction was pure acetone at 1.5 T and 90 v/v% at 3.0 T.
36
Routine clinical brain MRI sequences for use at 3.0 Tesla
Hanzhang Lu, Lidia M. Nagae‐Poetscher, Xavier Golay et al. · Journal of Magnetic Resonance Imaging · 2005 · 326 citations · Full text
Medicine, Neuroscience, Radiology +17
Postmortem verification of MS cortical lesion detection with 3D DIR
Alexandra Seewann, E.-J. Kooi, Stefan D. Roosendaal et al. · Neurology · 2012 · 226 citations · Full text
Medicine, Neurology, Neuroscience +17
Agarose as a tissue equivalent phantom material for NMR imaging
Matthew D. Mitchell, Harold L. Kundel, Leon Axel et al. · Magnetic Resonance Imaging · 1986 · 199 citations