Publication | Open Access
Comparison of Complication Rates between Manual and Femtosecond Laser-Assisted Techniques for Intrastromal Corneal Ring Segments Implantation in Keratoconus
30
Citations
31
References
2019
Year
<b>Purpose</b>: To compare the incidence of complications between manual and femtosecond-laser assisted surgery for intrastromal corneal ring segments (ICRS) implantation.<b>Material and methods</b>: This study included keratoconus patients who had ICRS implantation using manual dissection and using the femtosecond laser with a minimum follow-up of 12 months. Uncorrected (UDVA) corrected (CDVA) distance visual acuity (CDVA), refraction, corneal topography and aberrometry, pachymetry map and slit-lamp microscopy were assessed before and after surgery.<b>Results</b>: The study included 265 eyes in the manual group and 111 in the femtosecond laser group. In the manual group, there were complications in 48 eyes (18.11%); while in the femtosecond laser 4 eyes had a complication (3.6%). In the manual group, the most frequent complications were ICRS exchange/adjustment for visual and refractive enhancement (25 eyes; 9.43%) and late ICRS spontaneous extrusion (15 eyes; 5.66%). In the manual group, 81.25% of complications were observed during the first 3 years of surgeon's experience. Eyes who suffered a complication had preoperatively higher mean refractive (<i>p</i> = .002) and topographic cylinder (<i>p</i> = .003) and lower UDVA (<i>p</i> = .005) and CDVA (<i>p</i> = .002). After a second surgical procedure for complication management visual, refractive and topographic outcomes significantly improved.<b>Conclusion</b>: Manual mechanical ICRS surgery shows a higher rate of intra- and postoperative mechanical and refractive complications when compared to femtosecond laser assisted technique. The incidence is specially higher during the surgeon's first years of implementation of the technique.
| Year | Citations | |
|---|---|---|
Page 1
Page 1