Physics in Medicine and Biology · 2019 · 19 citations · 12 references
EngineeringNuclear EngineeringRadiologyDiagnostic ImagingNuclear InstrumentationRadiation DetectionDetector TechnologyGamma-ray DetectorsGamma-ray InstrumentationRadiation DetectorsRadiation Imaging DetectorsRadiation Imaging SystemsDetectorsFlat-panel Detector PerformanceFlat-panel Detector SystemsFlat-panel DetectorsGamma Camera ImagingGamma-ray Detector TechnologyNuclear Medicine DetectorsX-ray Imaging Performance
Abstract Simultaneous acquisition of nuclear and fluoroscopic projections could be of benefit for image-guided radionuclide administration. A gamma camera positioned behind an x-ray flat panel detector can accomplish such simultaneous acquisition, but the gamma camera performance suffers from the intense x-ray dose. A regular NaI(Tl)-based camera has nominal performance up to 0.02 nGy dose per pulse, whereas 10 nGy dose is expected for our foreseen applications. We evaluated the performance of CeBr 3 - and CZT-based detectors and investigated a cost-effective improvement of a regular NaI(Tl)-based camera by the introduction of a high-pass filter and shorting circuit. A CeBr 3 -based detector was exposed to 5 mGy x-ray dose and the resulting light emission was measured over time to quantify the crystal afterglow, allowing comparison with a previously measured NaI(Tl)-based detector. The NaI(Tl)-, CeBr 3 - and CZT-based detectors were exposed to x-ray pulse sequences with dose from 0.06 to 60 nGy, while being irradiated with a gamma source. The mean gamma energy and energy resolution in between the x-ray pulses were measured as a reference of the detector performance. The afterglow signal after 3 ms was 14.1% for the NaI(Tl)-based detector, whereas for the CeBr 3 -based detector it was only 0.1%. The limits for a proper functioning detectors are 0.32 nGy for the NaI(Tl)-based detector with high-pass filter and shorting circuit and 18.94 nGy for the one with CeBr 3 . No energy degradation was observed for the CZT module in the studied dose range. The performance of regular NaI(Tl)-based gamma cameras deteriorates when exposed to high x-ray doses. CeBr 3 and CZT are much better suited for introduction into a dual-layer detector but have high associated costs. Addition of a high-pass filter and shorting circuit into the PMT of a NaI(Tl)-based detector is a cost-effective solution that works well for low dose levels.
12
Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging
Jan S. Iwanczyk, E. Nygärd, Meirav Oded et al. · IEEE Transactions on Nuclear Science · 2009 · 293 citations · Full text
Description of a prototype emission-transmission computed tomography imaging system.
Thomas Lang, B.H. Hasegawa, Soo Chin Liew et al. · PubMed · 1992 · 175 citations
Myocardial perfusion imaging with a combined x-ray CT and SPECT system.
K. Kalki, Blankespoor Sc, Brown Jk et al. · PubMed · 1997 · 71 citations