Ablation-index guided versus conventional contact-force guided ablation in pulmonary vein isolation – Systematic review and meta-analysis

Raymond Pranata, Rachel Vania, Ian Huang

Indian Pacing and Electrophysiology Journal · 2019 · 49 citations · 11 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: Contact-force sensing catheter is widely used for catheter ablation, however, it did not take account of radiofrequency power. Ablation index (AI) is a novel marker incorporating contact force-time-power, was shown to be reliable in predicting lesion size and depth for radiofrequency delivery. We aimed to assess the latest evidence on ablation index guided procedure versus conventional ablation procedure. METHODS: We performed a comprehensive search on topic that assesses ablation index guided procedure versus conventional procedures from inception up until February 2019 through PubMed, EuropePMC, EBSCOhost, Cochrane Central Database, and ClinicalTrials.gov. RESULTS: 95%. Total procedural time and complication rate were similar. CONCLUSION: Ablation index guided procedure resulted in a significantly lower incidence of AF/AT/AFL, shorter fluoroscopy time, and total ablation time. First-pass isolation was higher in AI group and acute PVR was lower in AI group. Ablation-index guided procedure has a similar safety profile to conventional ablation.

References

11