Japanese Journal of Applied Physics · 2019 · 11 citations · 20 references
EngineeringRadiologyDiagnostic RadiologyRadiation DetectionRadiation MeasurementComputed TomographyComputed Tomography PhysicsRadiation DetectorsRadiation Imaging DetectorsX-ray DetectionX-ray DetectorsAttenuation MeasurementComputed Tomography DetectorsDetectorsEffective Atomic NumberElectron DensityLinear Attenuation CoefficientsRadiation Attenuation CoefficientsX-ray Attenuation Coefficients
Abstract We have developed a current-mode detector system, called a “transXend” detector, consisting of several segmented detectors aligned along the direction of X-ray incidence, for energy-resolved computed tomography (CT). The transXend detector measures X-rays as electric currents and after analysis gives the energy spectrum of the incident X-ray. In previous work, we measured the linear attenuation coefficients of resins as a function of X-ray energy with the energy-resolved CT using the transXend detector. This paper shows a method to estimate the effective atomic number <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>Z</mml:mi> </mml:mrow> <mml:mrow> <mml:mi mathvariant="normal">e</mml:mi> <mml:mi mathvariant="normal">f</mml:mi> <mml:mi mathvariant="normal">f</mml:mi> </mml:mrow> </mml:msub> </mml:math> and electron density <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>ρ</mml:mi> </mml:mrow> <mml:mrow> <mml:mi>e</mml:mi> </mml:mrow> </mml:msub> </mml:math> of nine resins from the linear attenuation coefficients using a photon–atom cross-section lookup table. The estimated <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>Z</mml:mi> </mml:mrow> <mml:mrow> <mml:mi mathvariant="normal">e</mml:mi> <mml:mi mathvariant="normal">f</mml:mi> <mml:mi mathvariant="normal">f</mml:mi> </mml:mrow> </mml:msub> </mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>ρ</mml:mi> </mml:mrow> <mml:mrow> <mml:mi>e</mml:mi> </mml:mrow> </mml:msub> </mml:math> agreed well with calibration lines with accuracies of about 2%.
20
The Fourier reconstruction of a head section
L. A. Shepp, B. F. Logan · IEEE Transactions on Nuclear Science · 1974 · 2.2K citations
Material differentiation by dual energy CT: initial experience
Thorsten R. C. Johnson, Bernhard Krauß, Martin Sedlmair et al. · European Radiology · 2006 · 1.5K citations