Processes · 2019 · 202 citations · 54 references
EngineeringBiological EngineeringEnvironmental EngineeringBioprocess EngineeringProcess ControlWastewater TreatmentActivated Sludge ProcessBiological Treatment ProcessesSludge ManagementSludge TreatmentWastewater BiotreatmentWastewater ManagementAerationAeration Energy ConsumptionAeration SystemsEnergy ConsumptionSupervisory Control SystemsWastewater BioreactorsWastewater Treatment PlantsWastewater Treatment Processes
In wastewater treatment, activated sludge requires adequate aeration for microbial oxygen supply, yet aeration consumes 50–90 % of plant electricity and is the largest cost driver, so operators must regularly maintain diffuser efficiency. The paper aims to describe aeration system design, classify systems, and identify key parameters and factors influencing aeration performance. Effective optimization hinges on installing suitable metering devices to gather relevant data, which then informs targeted improvements. Smart control systems using SCADA can reduce aeration energy consumption in activated sludge bioreactors.
Due to the key role of the biological decomposition process of organic compounds in wastewater treatment, a very important thing is appropriate aeration of activated sludge, because microorganisms have to be supplied with an appropriate amount of oxygen. Aeration is one of the most energy-consuming processes in the conventional activated sludge systems of wastewater treatment technology (may consume from 50% to 90% of electricity used by a plant), which makes it the most cost-generating process incurred by treatment plants. The paper presents the construction of aeration systems, their classification as well as parameters and factors that significantly affect the aeration process e.g., oxygen transfer efficiency, diffuser fouling, methods of dealing with diffuser fouling, diffuser selection. Additionally, there are briefly presented “smart control” systems in wastewater treatment and effect of application control strategy based on Supervisory Control and Data Acquisition system connected with the decrease in the energy consumption for aeration of bioreactors with activated sludge. It is noted that before the process is optimized, the system should be equipped with suitable metering devices. Only when relevant data is available, the improvements can be carried out. However, it’s important, that the operator should regularly maintain good condition and high efficiency of diffusers.
54
A Simplex Method for Function Minimization
J. A. Nelder, R. Mead · The Computer Journal · 1965 · 28.9K citations
Activated Sludge Model No.2d, ASM2D
Mogens Henze, Willi Gujer, Takahashi Mino et al. · Water Science & Technology · 1999 · 581 citations
Engineering, Chemical Engineering, Environmental Engineering +17
Stefano B. Longo, Benedetto Mirko d’Antoni, Michael Bongards et al. · Applied Energy · 2016 · 509 citations · Full text