IEEE Transactions on Biomedical Circuits and Systems · 2019 · 79 citations · 56 references
EngineeringCardiologyElectrical EngineeringBioinstrumentationBiomedical Signal ProcessingElectrophysiologyCardiac ArrhythmiasCardiac Signal ProcessingDigital Signal ProcessingElectrocardiogram AnalysisElectrocardiographySignal Detection TheoryArrhythmia DetectionArrhythmia DiagnosisDetectorsEcg Signal PreprocessingGroup DelayPeak DetectionQrs Complex DetectionR Peak Detection
This paper presents an efficient infinite impulse response type digital fractional order differentiator (DFOD) based electrocardiogram (ECG) pre-processor to detect QRS complexes. First, an efficient optimizer namely, Antlion optimization algorithm is employed to solve the proposed DFOD design problem. Then, the designed DFOD is deployed in the pre-processing stage of a threshold independent R-peak detection technique. Finally, the proposed QRS complex detector is thoroughly assessed on the standard ECG datasets of MIT/BIH Arrhythmia, MIT/BIH ST Change, MIT/BIH Supraventricular Arrhythmia, European ST-T, QT, and T-Wave Alternans Challenge databases to show the wide sense practicability of the proposed DFOD-based QRS detector. The root-means-square magnitude error (RMSME) and the average group delay (τ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DD</sub> ) metrics of the proposed DFOD are as low as -38.17 dB and 0.04 samples, respectively. The percentage of improvement in terms of RMSME metric compared to the bestreported approach is 15%. The overall sensitivity of 99.89% and positive predictivity of 99.88% are incurred by considering all the six databases. To the best of the authors' knowledge, it is the first time when the evolutionary algorithm based IIR-type DFOD is employed for the QRS complex detection and establishing its performance superiority. The results so obtained are compared with the results of all the recently reported QRS detectors. The proposed DFOD based ECG pre-processor has a great potential to robustly generate the feature signal related to the ECG QRS complex irrespective of the ECG morphology. Thus, the proposed DFOD based QRS detector can be employed in clinical ECG monitoring devices to augment the QRS detection performance.
56
PhysioBank, PhysioToolkit, and PhysioNet
Ary L. Goldberger, Luı́s A. Nunes Amaral, Leon Glass et al. · Circulation · 2000 · 14.5K citations · Full text
A Real-Time QRS Detection Algorithm
Jiapu Pan, W.J. Tompkins · IEEE Transactions on Biomedical Engineering · 1985 · 7.7K citations
Seyedali Mirjalili · Advances in Engineering Software · 2015 · 3.2K citations